Literature DB >> 27661786

Determination of volatile polycyclic aromatic hydrocarbons in waters using headspace solid-phase microextraction with a benzyl-functionalized crosslinked polymeric ionic liquid coating.

Melek Merdivan1, Verónica Pino2, Jared L Anderson3.   

Abstract

A benzyl-functionalized crosslinked polymeric ionic liquid (PIL), produced through the co-polymerization of the 1-vinylbenzyl-3-hexadecylimidazolium bis[(trifluoromethyl)sulfonyl]imide (VBHDIM-NTf2) ionic liquid (IL) monomer and 1,12-di(3-vinylbenzylimidazolium)dodecane bis[(trifluoromethyl)sulfonyl]imide ((DVBIM)2C12-2NTf2) IL crosslinker, was successfully used as a sorbent coating in headspace solid-phase microextraction (SPME) coupled to gas chromatography (GC) with flame-ionization detection (FID) to determine seven volatile polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Optimum extraction conditions for the PAHs when using the novel sorbent include an extraction temperature of 50°C, an ionic strength content adjusted with 30% (w/v) NaCl in the aqueous sample, and an extraction time of 60 min. The extraction performance of the crosslinked PIL fiber was compared to the SPME commercial coating polydimethylsiloxane fiber. The calibration ranges of the studied PAHs were linear in the range of 0.02-20 µg L-1 for the crosslinked PIL fiber. The accuracy of the proposed method was demonstrated by examining the spiked recoveries of seven PAHs which produced values ranging from 67.2% to 130% (for river- and seawater samples), and precision values lower than 9.4% for a spiked level of 1 µg L-1, and detection limits between 0.01 and 0.04 µg L-1, which supports the sensitivity of the method using GC-FID.

Entities:  

Keywords:  Polycyclic aromatic hydrocarbons; environmental water samples; gas chromatography; headspace solid-phase microextraction; polymeric ionic liquid

Mesh:

Substances:

Year:  2016        PMID: 27661786     DOI: 10.1080/09593330.2016.1240242

Source DB:  PubMed          Journal:  Environ Technol        ISSN: 0959-3330            Impact factor:   3.247


  2 in total

1.  Determination of Volatile Water Pollutants Using Cross-Linked Polymeric Ionic Liquid as Solid Phase Micro-Extraction Coatings.

Authors:  Yuan Tian; Xilan Feng; Yuping Zhang; Quan Yu; Xiaohao Wang; Mengkui Tian
Journal:  Polymers (Basel)       Date:  2020-02-02       Impact factor: 4.329

Review 2.  Recent Advances in Applications of Ionic Liquids in Miniaturized Microextraction Techniques.

Authors:  Maria Kissoudi; Victoria Samanidou
Journal:  Molecules       Date:  2018-06-13       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.