Literature DB >> 27661568

Monochromatic measurements of the JPSS-1 VIIRS polarization sensitivity.

Jeff McIntire, David Moyer, Steven W Brown, Keith R Lykke, Eugene Waluschka, Hassan Oudrari, Xiaoxiong Xiong.   

Abstract

Polarization sensitivity is a critical property that must be characterized for spaceborne remote sensing instruments designed to measure reflected solar radiation. Broadband testing of the first Joint Polar-orbiting Satellite System (JPSS-1) Visible Infrared Imaging Radiometer Suite (VIIRS) showed unexpectedly large polarization sensitivities for the bluest bands on VIIRS (centered between 400 and 600 nm). Subsequent ray trace modeling indicated that large diattenuation on the edges of the bandpass for these spectral bands was the driver behind these large sensitivities. Additional testing using the National Institute of Standards and Technology's Traveling Spectral Irradiance and Radiance Responsivity Calibrations Using Uniform Sources was added to the test program to verify and enhance the model. The testing was limited in scope to two spectral bands at two scan angles; nonetheless, this additional testing provided valuable insight into the polarization sensitivity. Analysis has shown that the derived diattenuation agreed with the broadband measurements to within an absolute difference of about 0.4% and that the ray trace model reproduced the general features of the measured data. Additionally, by deriving the spectral responsivity, the linear diattenuation is shown to be explicitly dependent on the changes in bandwidth with polarization state.

Entities:  

Year:  2016        PMID: 27661568      PMCID: PMC5584381          DOI: 10.1364/AO.55.007444

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  3 in total

1.  Moderate-resolution imaging spectroradiometer ocean color polarization correction.

Authors:  Gerhard Meister; Ewa J Kwiatkowska; Bryan A Franz; Frederick S Patt; Gene C Feldman; Charles R McClain
Journal:  Appl Opt       Date:  2005-09-10       Impact factor: 1.980

2.  Facility for spectral irradiance and radiance responsivity calibrations using uniform sources.

Authors:  Steven W Brown; George P Eppeldauer; Keith R Lykke
Journal:  Appl Opt       Date:  2006-11-10       Impact factor: 1.980

3.  Comparison of two methodologies for calibrating satellite instruments in the visible and near-infrared.

Authors:  Robert A Barnes; Steven W Brown; Keith R Lykke; Bruce Guenther; James J Butler; Thomas Schwarting; Kevin Turpie; David Moyer; Frank DeLuccia; Christopher Moeller
Journal:  Appl Opt       Date:  2015-12-10       Impact factor: 1.980