Literature DB >> 27661389

ToF-SIMS and Laser-SNMS Imaging of Heterogeneous Topographically Complex Polymer Systems.

Andreas Pelster1, Martin Körsgen1, Takako Kurosawa2, Hiromi Morita2, Heinrich F Arlinghaus1.   

Abstract

Heterogeneous polymer coatings, such as those used in organic electronics and medical devices, are of increasing industrial importance. In order to advance the development of these types of systems, analytical techniques are required which are able to determine the elemental and molecular spatial distributions, on a nanometer scale, with very high detection efficiency and sensitivity. The goal of this study was to investigate the suitability of laser postionization secondary neutral mass spectrometry (Laser-SNMS) with a 157 nm postionization laser beam to image structured polymer mixtures and compare the results with time-of-flight secondary ion mass spectrometry (ToF-SIMS) measurements using Bi3+ primary ions. The results showed that Laser-SNMS is better suited than ToF-SIMS for unambiguous detection and submicrometer imaging of the wide range of polymers investigated. The data also showed that Laser-SNMS has the advantage of being much more sensitive (in general higher by more than an order of magnitude and peaking at up to 3 orders of magnitude) than ToF-SIMS while also showing superior performance on topographically complex structured insulating surfaces, due to significantly reduced field effects and a higher dynamic range as compared to ToF-SIMS. It is concluded that Laser-SNMS is a powerful complementary technique to ToF-SIMS for the analysis of heterogeneous polymers and other complex structured organic mixtures, providing submicrometer resolution and high sensitivity.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27661389     DOI: 10.1021/acs.analchem.6b02415

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Development, characterization, and first application of a resonant laser secondary neutral mass spectrometry setup for the research of plutonium in the context of long-term nuclear waste storage.

Authors:  Daniela Schönenbach; Felix Berg; Markus Breckheimer; Daniel Hagenlocher; Pascal Schönberg; Raphael Haas; Samer Amayri; Tobias Reich
Journal:  Anal Bioanal Chem       Date:  2021-05-10       Impact factor: 4.142

2.  Ambient Characterization of Synthetic Fibers by Laser Ablation Electrospray Ionization Mass Spectrometry.

Authors:  Fred A M G van Geenen; Maurice C R Franssen; Anton H M Schotman; Han Zuilhof; Michel W F Nielen
Journal:  Anal Chem       Date:  2017-03-14       Impact factor: 6.986

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.