Literature DB >> 27660905

Sources of Circuit Thrombosis in Pediatric Extracorporeal Membrane Oxygenation.

Susan M Hastings1, David N Ku, Scott Wagoner, Kevin O Maher, Shriprasad Deshpande.   

Abstract

Extracorporeal membrane oxygenation (ECMO) for cardiopulmonary support of critically ill patients is used frequently in the pediatric population. ECMO is burdened by complications, including thrombosis and hemorrhage. Here we demonstrate the focused location of clots, their histologic composition, and the relationship of in situ thrombus to local hemodynamics in ECMO circuits. Pediatric ECMO circuits from Children's Healthcare of Atlanta, Emory University (Atlanta, GA) were obtained after removal from extracorporeal support over a 2.5 year period (n = 50). All clots and material deposited within the circuit were recorded. Location of clot was compared with local hemodynamics. Most clots were adherent to the junctions made by the tubing and connectors, as opposed to being randomly disturbed throughout the circuit tubing (p << 0.05). Loose, nonadherent clots were also found at the entry side of oxygenators. The clots colocated directly with zones of low shear rate. Histology revealed a fibrinous composition, consistent with coagulation potentiated by low shear. Centrifugal pump circuits (n = 16) had more clots than roller pump (n = 34) circuits (p << 0.05). In addition, all centrifugal pumps had clots that formed at the top of the pump shaft. The ECMO circuits from our single-center study demonstrate the concentrated location of fibrin clots at low shear zones created by tubing-connector junctions. Type of pump also influences the frequency of clot formation. Since the mechanism of the majority of ECMO circuit thrombosis is low shear and fibrin driven, optimization of hemodynamics and anticoagulation regimen may reduce clot formation and bleeding.

Entities:  

Mesh:

Year:  2017        PMID: 27660905     DOI: 10.1097/MAT.0000000000000444

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  19 in total

Review 1.  Extracorporeal membrane oxygenation in the pre and post lung transplant period.

Authors:  Nirmal S Sharma; Mathew G Hartwig; Don Hayes
Journal:  Ann Transl Med       Date:  2017-02

2.  The impact of shear stress on device-induced platelet hemostatic dysfunction relevant to thrombosis and bleeding in mechanically assisted circulation.

Authors:  Zengsheng Chen; Jiafeng Zhang; Tieluo Li; Douglas Tran; Bartley P Griffith; Zhongjun J Wu
Journal:  Artif Organs       Date:  2019-12-17       Impact factor: 3.094

3.  Mathematical and Computational Modeling of Device-Induced Thrombosis.

Authors:  Keefe B Manning; Franck Nicoud; Susan M Shea
Journal:  Curr Opin Biomed Eng       Date:  2021-09-28

Review 4.  Extracorporeal membrane oxygenation in children receiving haematopoietic cell transplantation and immune effector cell therapy: an international and multidisciplinary consensus statement.

Authors:  Matteo Di Nardo; Ali H Ahmad; Pietro Merli; Matthew S Zinter; Leslie E Lehman; Courtney M Rowan; Marie E Steiner; Sangeeta Hingorani; Joseph R Angelo; Hisham Abdel-Azim; Sajad J Khazal; Basirat Shoberu; Jennifer McArthur; Rajinder Bajwa; Saad Ghafoor; Samir H Shah; Hitesh Sandhu; Karen Moody; Brandon D Brown; Maria E Mireles; Diana Steppan; Taylor Olson; Lakshmi Raman; Brian Bridges; Christine N Duncan; Sung Won Choi; Rita Swinford; Matt Paden; James D Fortenberry; Giles Peek; Pierre Tissieres; Daniele De Luca; Franco Locatelli; Selim Corbacioglu; Martin Kneyber; Alessio Franceschini; Simon Nadel; Matthias Kumpf; Alessandra Loreti; Roelie Wösten-Van Asperen; Orsola Gawronski; Joe Brierley; Graeme MacLaren; Kris M Mahadeo
Journal:  Lancet Child Adolesc Health       Date:  2021-12-09

5.  Effect of blood flow on platelets, leukocytes, and extracellular vesicles in thrombosis of simulated neonatal extracorporeal circulation.

Authors:  Andrew D Meyer; Anjana R Rishmawi; Robin Kamucheka; Crystal Lafleur; Andriy I Batchinsky; Nigel Mackman; Andrew P Cap
Journal:  J Thromb Haemost       Date:  2019-11-14       Impact factor: 5.824

6.  Development of Coagulation Factor XII Antibodies for Inhibiting Vascular Device-Related Thrombosis.

Authors:  T C L Kohs; C U Lorentz; J Johnson; C Puy; S R Olson; J J Shatzel; D Gailani; M T Hinds; E I Tucker; A Gruber; O J T McCarty; M Wallisch
Journal:  Cell Mol Bioeng       Date:  2020-10-13       Impact factor: 2.321

7.  Fibrinogen Albumin Ratio and Ischemic Stroke During Venoarterial Extracorporeal Membrane Oxygenation.

Authors:  Prakash Acharya; William A Jakobleff; Stephen J Forest; Thiru Chinnadurai; Nicolas Mellas; Snehal R Patel; Jorge R Kizer; Henny H Billett; Daniel J Goldstein; Ulrich P Jorde; Omar Saeed
Journal:  ASAIO J       Date:  2020-03       Impact factor: 3.826

8.  Investigation of the influence of fluid dynamics on thrombus growth at the interface between a connector and tube.

Authors:  Yuki Matsuhashi; Kei Sameshima; Yoshiki Yamamoto; Mitsuo Umezu; Kiyotaka Iwasaki
Journal:  J Artif Organs       Date:  2017-07-28       Impact factor: 1.731

Review 9.  Advances in extracorporeal membrane oxygenator design for artificial placenta technology.

Authors:  David G Blauvelt; Emily N Abada; Peter Oishi; Shuvo Roy
Journal:  Artif Organs       Date:  2020-11-04       Impact factor: 3.094

10.  Real-time visualization of thrombus formation at the interface between connectors and tubes in medical devices by using optical coherence tomography.

Authors:  Yuki Matsuhashi; Kei Sameshima; Yoshiki Yamamoto; Mitsuo Umezu; Kiyotaka Iwasaki
Journal:  PLoS One       Date:  2017-12-07       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.