Sample-to-answer on molecular diagnosis of bacterial infection using integrated lab--on--a--disc.

J F C Loo1, H C Kwok2, C C H Leung3, S Y Wu2, I L G Law4, Y K Cheung5, Y Y Cheung6, M L Chin6, P Kwan5, M Hui6, S K Kong4, H P Ho7.   

Abstract

Sepsis by bacterial infection causes high mortality in patients in intensive care unit (ICU). Rapid identification of bacterial infection is essential to ensure early appropriate administration of antibiotics to save lives of patients, yet the present benchtop molecular diagnosis is time-consuming and labor-intensive, which limits the treatment efficiency especially when the number of samples to be tested is extensive. Therefore, we hereby report a microfluidic platform lab-on-a-disc (LOAD) to provide a sample-to-answer solution. Our LOAD customized design of microfluidic channels allows automation to mimic sequential analytical steps in benchtop environment. It relies on a simple but controllable centrifugation force for the actuation of samples and reagents. Our LOAD system performs three major functions, namely DNA extraction, isothermal DNA amplification and real-time signal detection, in a predefined sequence. The disc is self-contained for conducting sample heating with chemical lysis buffer and silica microbeads are employed for DNA extraction from clinical specimens. Molecular diagnosis of specific target bacteria DNA sequences is then performed using a real-time loop-mediated isothermal amplification (RT-LAMP) with SYTO-9 as the signal reporter. Our LOAD system capable of bacterial identification of Mycobacterium tuberculosis (TB) and Acinetobacter baumanii (Ab) with the detection limits 103cfu/mL TB in sputum and 102cfu/mL Ab in blood within 2h after sample loading. The reported LOAD based on an integrated approach should address the growing needs for rapid point-of-care medical diagnosis in ICU.
Copyright © 2016. Published by Elsevier B.V.

Entities:  

Keywords:  Infectious disease diagnosis; Lab-­on-­a-disc; Loop-­mediated isothermal amplification; Sample-to-answer

Mesh:

Substances:

Year:  2016        PMID: 27660018     DOI: 10.1016/j.bios.2016.09.001

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  11 in total

Review 1.  Point-of-care diagnostics for infectious diseases: From methods to devices.

Authors:  Chao Wang; Mei Liu; Zhifei Wang; Song Li; Yan Deng; Nongyue He
Journal:  Nano Today       Date:  2021-02-06       Impact factor: 20.722

Review 2.  Integrated microfluidic systems with sample preparation and nucleic acid amplification.

Authors:  Juxin Yin; Yuanjie Suo; Zheyu Zou; Jingjing Sun; Shan Zhang; Beng Wang; Yawei Xu; Diane Darland; Julia Xiaojun Zhao; Ying Mu
Journal:  Lab Chip       Date:  2019-07-31       Impact factor: 6.799

Review 3.  Point-of-critical-care diagnostics for sepsis enabled by multiplexed micro and nanosensing technologies.

Authors:  Brandon K Ashley; Umer Hassan
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2021-03-01

4.  Automated multiplex nucleic acid tests for rapid detection of SARS-CoV-2, influenza A and B infection with direct reverse-transcription quantitative PCR (dirRT-qPCR) assay in a centrifugal microfluidic platform.

Authors:  Minghui Ji; Yun Xia; Jacky Fong-Chuen Loo; Lang Li; Ho-Pui Ho; Jianan He; Dayong Gu
Journal:  RSC Adv       Date:  2020-09-15       Impact factor: 4.036

5.  Evaluation of Nucleic Acid Isothermal Amplification Methods for Human Clinical Microbial Infection Detection.

Authors:  Brett E Etchebarne; Zenggang Li; Robert D Stedtfeld; Michael C Nicholas; Maggie R Williams; Timothy A Johnson; Tiffany M Stedtfeld; Tanja Kostic; Walid T Khalife; James M Tiedje; Syed A Hashsham; Mary J Hughes
Journal:  Front Microbiol       Date:  2017-12-12       Impact factor: 5.640

6.  Synergistically enhanced colorimetric molecular detection using smart cup: a case for instrument-free HPV-associated cancer screening.

Authors:  Kun Yin; Vikram Pandian; Karteek Kadimisetty; Carlos Ruiz; Kumarasen Cooper; Jianxin You; Changchun Liu
Journal:  Theranostics       Date:  2019-04-13       Impact factor: 11.556

Review 7.  Development of Point-of-Care Biosensors for COVID-19.

Authors:  Jane Ru Choi
Journal:  Front Chem       Date:  2020-05-27       Impact factor: 5.221

Review 8.  Micro/nano biomedical devices for point-of-care diagnosis of infectious respiratory diseases.

Authors:  Yang Wang; Huiren Xu; Zaizai Dong; Zhiying Wang; Zhugen Yang; Xinge Yu; Lingqian Chang
Journal:  Med Nov Technol Devices       Date:  2022-02-12

Review 9.  Microfluidics-based strategies for molecular diagnostics of infectious diseases.

Authors:  Xin Wang; Xian-Zhe Hong; Yi-Wei Li; Ying Li; Jie Wang; Peng Chen; Bi-Feng Liu
Journal:  Mil Med Res       Date:  2022-03-18

10.  Development of a proof-of-concept microfluidic portable pathogen analysis system for water quality monitoring.

Authors:  Hamsa N Gowda; Horacio Kido; Xunyi Wu; Oren Shoval; Adrienne Lee; Albert Lorenzana; Marc Madou; Michael Hoffmann; Sunny C Jiang
Journal:  Sci Total Environ       Date:  2021-12-21       Impact factor: 7.963

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.