| Literature DB >> 27655803 |
Tran Xuan Hoi1,2, Huynh Truc Phuong2, Nguyen Van Hung3.
Abstract
Besides the most common methods of internal dose assessment from inhaled 131I, that are thyroid monitoring and urine analysis, air sampling is a possible way but rarely used for dose estimate. This study aimed to focus on the utilisation of portable air sampler to estimate the internal dose for workers working at 131I production facility. In addition, internal dose estimated from urine analysis at the same time was carried out for comparison. Based on this research, it was found that air monitoring can be done efficiently as urine monitoring if the following conditions are met: (1) the indoor areas are not large, (2) sampling sites need to be placed as near breathing zone as possible and (3) the time-micro-environment patterns of monitored workers are collected carefully.Entities:
Mesh:
Substances:
Year: 2017 PMID: 27655803 DOI: 10.1093/rpd/ncw269
Source DB: PubMed Journal: Radiat Prot Dosimetry ISSN: 0144-8420 Impact factor: 0.972