Literature DB >> 27654010

A methodology for constraining power in finite element modeling of radiofrequency ablation.

Yansheng Jiang1, Ricardo Possebon2, Stefaan Mulier1,3, Chong Wang2, Feng Chen4, Yuanbo Feng1, Qian Xia5, Yewei Liu1, Ting Yin1, Raymond Oyen1, Yicheng Ni1.   

Abstract

Radiofrequency ablation (RFA) is a minimally invasive thermal therapy for the treatment of cancer, hyperopia, and cardiac tachyarrhythmia. In RFA, the power delivered to the tissue is a key parameter. The objective of this study was to establish a methodology for the finite element modeling of RFA with constant power. Because of changes in the electric conductivity of tissue with temperature, a nonconventional boundary value problem arises in the mathematic modeling of RFA: neither the voltage (Dirichlet condition) nor the current (Neumann condition), but the power, that is, the product of voltage and current was prescribed on part of boundary. We solved the problem using Lagrange multiplier: the product of the voltage and current on the electrode surface is constrained to be equal to the Joule heating. We theoretically proved the equality between the product of the voltage and current on the surface of the electrode and the Joule heating in the domain. We also proved the well-posedness of the problem of solving the Laplace equation for the electric potential under a constant power constraint prescribed on the electrode surface. The Pennes bioheat transfer equation and the Laplace equation for electric potential augmented with the constraint of constant power were solved simultaneously using the Newton-Raphson algorithm. Three problems for validation were solved. Numerical results were compared either with an analytical solution deduced in this study or with results obtained by ANSYS or experiments. This work provides the finite element modeling of constant power RFA with a firm mathematical basis and opens pathway for achieving the optimal RFA power.
Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  Lagrange multiplier; finite element; power constraint; radiofrequency ablation

Mesh:

Year:  2016        PMID: 27654010     DOI: 10.1002/cnm.2834

Source DB:  PubMed          Journal:  Int J Numer Method Biomed Eng        ISSN: 2040-7939            Impact factor:   2.747


  1 in total

1.  A piecewise function of resistivity of liver: determining parameters with finite element analysis of radiofrequency ablation.

Authors:  Ricardo Possebon; Yansheng Jiang; Stefaan Mulier; Chong Wang; Feng Chen; Yuanbo Feng; Yicheng Ni
Journal:  Med Biol Eng Comput       Date:  2017-08-02       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.