Literature DB >> 27653376

The effect of the extensor mechanism on maximum isometric fingertip forces: A numerical study on the index finger.

A Synek1, D H Pahr2.   

Abstract

The extensor mechanism is a tendinous network connecting intrinsic and extrinsic muscles of the finger and its function has not yet been fully understood. The goal of this study was to assess the effect of the extensor mechanism on the maximum isometric fingertip forces - a parameter which is essential for grasping. For this purpose, maximum fingertip forces in all directions (i.e. feasible force sets) of two musculoskeletal models of the index finger were compared: the wEM model included a full representation of the extensor mechanism, whereas in the noEM model the extensor mechanism was replaced by a single extensor tendon without connectivity to intrinsic muscles. The feasible force sets were computed in the flexion-extension plane for nine postures. Forces in four predefined directions (palmar, proximal, dorsal, and distal), and the peak resultant forces were evaluated. Averaged forces in all four predefined directions were considerably larger in the wEM model (+187.6%). However, peak resultant forces were slightly lower in the wEM model (-4.3% on average). The general advantage of the wEM model could be explained by co-contraction of intrinsic and extrinsic extensor muscles which allowed reaching larger activation levels of the extrinsic flexors. Only within a narrow range of force directions the co-contraction of intrinsic muscles limited the fingertip forces and lead to lower peak resultant forces in the wEM model. Rather than maximizing peak resultant forces, it appears that the extensor mechanism is a sophisticated tool for increasing maximum fingertip forces over a broad range of postures and force directions - making the finger more versatile during grasping.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Keywords:  Biomechanics; Extensor mechanism; Finger; Fingertip force; Grip force; Musculoskeletal

Mesh:

Year:  2016        PMID: 27653376     DOI: 10.1016/j.jbiomech.2016.09.004

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Metacarpophalangeal joint loads during bonobo locomotion: model predictions versus proxies.

Authors:  Alexander Synek; Szu-Ching Lu; Sandra Nauwelaerts; Dieter H Pahr; Tracy L Kivell
Journal:  J R Soc Interface       Date:  2020-03-04       Impact factor: 4.118

2.  Musculoskeletal models of a human and bonobo finger: parameter identification and comparison to in vitro experiments.

Authors:  Alexander Synek; Szu-Ching Lu; Evie E Vereecke; Sandra Nauwelaerts; Tracy L Kivell; Dieter H Pahr
Journal:  PeerJ       Date:  2019-08-09       Impact factor: 2.984

3.  Analysis on synergistic cocontraction of extrinsic finger flexors and extensors during flexion movements: A finite element digital human hand model.

Authors:  Ying Lv; Qingli Zheng; Xiubin Chen; Chunsheng Hou; Meiwen An
Journal:  PLoS One       Date:  2022-05-11       Impact factor: 3.240

4.  Feasibility Theory Reconciles and Informs Alternative Approaches to Neuromuscular Control.

Authors:  Brian A Cohn; May Szedlák; Bernd Gärtner; Francisco J Valero-Cuevas
Journal:  Front Comput Neurosci       Date:  2018-09-11       Impact factor: 2.380

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.