| Literature DB >> 27651824 |
Makoto Ohnishi1, Masaaki Suzuki1, Masahiro Yamamoto1, Tatsuya Kasai1, Hirokazu Kano1, Hideki Senoh1, Ichiro Higashikubo2, Akihiro Araki2, Shoji Fukushima1.
Abstract
BACKGROUND: Previously, we have developed and reported the method of measuring multi-walled carbon nanotube (MWCNT) in the lung from rats exposed to MWCNT intratracheally. The present research was performed to improve the analytical method of MWCNT to measure multiple samples in a short period of time. For the xanalysis of MWCNTs from tissues, the existence of carbon black may interfere. Therefore, it was examined whether or not carbon black interfere the determination of MWCNT in the standard solutions. Then, MWCNTs were administered to rats and the MWCNTs were determined in the rats by the new method and the recovery rates and time for determination were calculated. The standard solutions for MWCNTs and carbon black were prepared, and the concentrations in the solutions were determined by HPLC with checking their linearity between the concentrations and signal intensities. The reproducibility of the determination was also checked.Entities:
Keywords: Benzo[ghi]perylene; Carbon black; HPLC; Improved method; Intratracheally; Lungs; Multi-walled carbon nanotubes; Quantitation; Rats; Validation
Year: 2016 PMID: 27651824 PMCID: PMC5024449 DOI: 10.1186/s12995-016-0132-7
Source DB: PubMed Journal: J Occup Med Toxicol ISSN: 1745-6673 Impact factor: 2.646
Fig. 1A newly developed for MWCNT. a Lung tissue with the C99 at room temperature. b Lung digestion in C99. c Centrifugation of lung solution at 12,000 rpm for 10 min. d Supernatant removal and 60 % sulfuric acid addition to MWCNT samples. e MWCNT-marker hybrid method: Marker adsorbtion onto MWCNT for 15 min. f MWCNTs adhering to Nuclepore membrane filters were extracted with marker on MWCNTs. g Filter with MWCNT was then punched out in circular disks h Addition of 1 ml acetonitrile, stirring, followed by the extraction of the marker in MWCNTs and the acetonitrile filtration of marker in the MWCNTs. i HPLC analysis
Fig. 2Calibration curves of MWCNT and CB
Reproducibility of MWCNT using improve method
| MWCNT | No. of samples | Measurement value (μg/mL) | SD (μg/mL) | C.V.(%) |
|---|---|---|---|---|
| 0.2 μg/mL | 20 | 0.193 | 0.017 | 8.7 |
| 1.0 μg/mL | 20 | 0.995 | 0.069 | 6.9 |
MWCNT measurements in the lung by intratracheal administration
| MWCNT | No. of samples | Measurement value (μg/lung) | SD (μg/lung) | Recovery (%) |
|---|---|---|---|---|
| 60 μg | 5 | 60.4 | 15.9 | 101 |
| 120 μg | 5 | 122.3 | 36.3 | 102 |