Literature DB >> 27650821

Histologic Evaluation of Biopsy Specimens Obtained After Rotator Cuff Repair Augmented With a Highly Porous Collagen Implant.

Steven P Arnoczky1, Shariff K Bishai2, Brian Schofield3, Scott Sigman4, Brad D Bushnell5, Jan Pieter Hommen6, Craig Van Kampen7.   

Abstract

PURPOSE: To histologically evaluate biopsy specimens from patients who previously underwent rotator cuff repair augmented with a highly porous collagen implant.
METHODS: Biopsies of collagen implant/host-tissue constructs were obtained from 7 patients undergoing a second arthroscopic procedure at various time periods (5 weeks to 6 months) after arthroscopic rotator cuff repair augmented with a collagen implant overlay. The biopsy specimens were examined histologically for host-tissue ingrowth, host-tissue maturation, and host-implant biocompatibility.
RESULTS: At the earliest time period (5 weeks), the biopsy revealed the presence of host cells (fibroblasts) within the interstices of the porous collagen implant. Cells were aligned along the linear orientation of the collagen implant structure, and there was evidence of early collagen formation. The 3-month biopsies showed increased collagen formation, maturation, and organization over the surface of the implant and evidence of the collagen implant. At 6 months, the newly generated tissue had the histologic appearance of a tendon, suggesting functional loading of the new generated host tissue. There was no evidence of any remnants of the collagen implant in the 6-month biopsy. There was no evidence of any inflammatory or foreign body reaction within any of the tissue samples.
CONCLUSIONS: Biopsies of collagen implants retrieved from human rotator cuff repair subjects revealed cellular incorporation, tissue formation and maturation, implant resorption, and biocompatibility. CLINICAL RELEVANCE: The histologic observations from these clinical biopsies support the biocompatibility of this implant and its ability to promote new connective tissue with the histological appearance of tendon over the surface of the native cuff tendon.
Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27650821     DOI: 10.1016/j.arthro.2016.06.047

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  12 in total

Review 1.  Biologic and Synthetic Grafts in the Reconstruction of Large to Massive Rotator Cuff Tears.

Authors:  Robert J Gillespie; Derrick M Knapik; Ozan Akkus
Journal:  J Am Acad Orthop Surg       Date:  2016-12       Impact factor: 3.020

2.  Design of 3D Hybrid Plant Extract/Marine and Bovine Collagen Matrixes as Potential Dermal Scaffolds for Skin Wound Healing.

Authors:  Aida Lahmar; Maroua Rjab; Fairouz Sioud; Mouna Selmi; Abir Salek; Soumaya Kilani-Jaziri; Leila Chekir Ghedira
Journal:  ScientificWorldJournal       Date:  2022-06-30

3.  Treatment of Partial-Thickness Rotator Cuff Tears With a Resorbable Bioinductive Bovine Collagen Implant: 1-Year Results From a Prospective Multicenter Registry.

Authors:  Brandon D Bushnell; Shariff K Bishai; Ryan J Krupp; Sean McMillan; Brian A Schofield; Scott W Trenhaile; Louis F McIntyre
Journal:  Orthop J Sports Med       Date:  2021-08-13

Review 4.  The Role of Biologic Therapy in Rotator Cuff Tears and Repairs.

Authors:  Michael D Charles; David R Christian; Brian J Cole
Journal:  Curr Rev Musculoskelet Med       Date:  2018-03

Review 5.  Non-acute Rotator Cuff Tear: Repair Augmented with Reconstituted Absorbable Collagen Scaffold (RACS)- Systematic Review.

Authors:  Sruthi Priyavadhana; Munis Ashraf; Vishaal Sakthivelan; Prabhudev Prasad Purudappa; Varatharaj Mounasamy; Senthil Sambandam
Journal:  Arch Bone Jt Surg       Date:  2021-03

6.  Retear rates and clinical outcomes at 1 year after repair of full-thickness rotator cuff tears augmented with a bioinductive collagen implant: a prospective multicenter study.

Authors:  Brandon D Bushnell; Patrick M Connor; Howard W Harris; Charles P Ho; Scott W Trenhaile; Jeffrey S Abrams
Journal:  JSES Int       Date:  2020-12-15

7.  Arthroscopic Hip Capsular Plication With Augmentation Using a Bioinductive Collagen Implant.

Authors:  Stephen J Torres; Michael B Banffy
Journal:  Arthrosc Tech       Date:  2020-06-25

Review 8.  The Role of Collagen-Based Biomaterials in Chronic Wound Healing and Sports Medicine Applications.

Authors:  David A Yeung; Natalie H Kelly
Journal:  Bioengineering (Basel)       Date:  2021-01-08

9.  Tips and Tricks for Augmenting Rotator Cuff Repair With a Bio-inductive Collagen Implant.

Authors:  Lauren Pupa; Mihir Sheth; Neal Goldenberg; Theodore Shybut
Journal:  Arthrosc Tech       Date:  2021-11-09

10.  Full-Thickness Rotator Cuff Tears Can Be Safely Treated With a Resorbable Bioinductive Bovine Collagen Implant: One-Year Results of a Prospective, Multicenter Registry.

Authors:  Louis F McIntyre; Sean McMillan; Scott W Trenhaile; Shariff K Bishai; Brandon D Bushnell
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-08-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.