Literature DB >> 27642775

Efficacy of high-pitch CT protocols for radiation dose reduction.

N Guberina1, U Lechel, M Forsting, A Ringelstein.   

Abstract

Various strategies have been developed to reduce radiation exposure of patients in CT examinations. The aim of this study was to evaluate the efficacy of high pitch in representative CT protocols examining lung embolism. We performed thermoluminescence measurements with an anthropomorphic phantom exposing it to CT algorithms for lung embolism in a 128-multislice, dual-source CT scanner: a standard CT protocol (sCT) and a CT protocol with a high pitch (+ F). Radiation doses for both CT algorithms were compared and the dose reduction potential of high pitch for individual organs was evaluated. As expected, the  +F mode reduced the effective dose and organ doses in the primary beam of radiation (namely, lung, bone marrow, heart, breast, skin and skeleton) compared with sCT by up to 52% for an equivalent image quality. On the contrary, for organs at the margin of the primary beam (thymus, thyroid, liver, pancreas, kidneys, colon and small intestine), the  +F mode reduced effective radiation doses by only 0-30%, compared with sCT. The dose reduction potential of the  +F mode greatly depends on the position of the organ in the scan field. While for organs in the primary beam  + F leads to a considerable dose reduction, it is less effective for tissues at the margin of the scanned area.

Entities:  

Mesh:

Year:  2016        PMID: 27642775     DOI: 10.1088/0952-4746/36/4/N57

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  4 in total

1.  Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

Authors:  Nika Guberina; Michael Forsting; Adrian Ringelstein; Saravanabavaan Suntharalingam; Kai Nassenstein; Jens Theysohn; Axel Wetter
Journal:  Eur Radiol       Date:  2018-03-28       Impact factor: 5.315

2.  Image quality and radiation dose of ECG-triggered High-Pitch Dual-Source cardiac computed tomography angiography in children for the evaluation of central vascular stents.

Authors:  Christian A Barrera; Hansel J Otero; Ammie M White; David Saul; David M Biko
Journal:  Int J Cardiovasc Imaging       Date:  2019-01-25       Impact factor: 2.357

Review 3.  State-of-the-Art Imaging for the Evaluation of Pulmonary Embolism.

Authors:  Leonid Roshkovan; Harold Litt
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-08-07

4.  Feasibility analysis of high pitch cervical spine CT in uncooperative patients with acute cervical spine trauma: An initial experience.

Authors:  Juntao Cao; Na Xie; Pingkang Qian; Ming Hu; Jianchun Tu
Journal:  Medicine (Baltimore)       Date:  2022-09-30       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.