| Literature DB >> 27642317 |
Samira Eslamizad1, Hassan Yazdanpanah2, Katayon Javidnia3, Ramezan Sadeghi4, Mitra Bayat5, Sara Shahabipour5, Najmeh Khalighian5, Farzad Kobarfard6.
Abstract
A fast and simple modified QuEChERS (quick, easy, cheap, rugged and safe) extraction method based on spiked calibration curves and direct sample introduction was developed for determination of Benzo [a] pyrene (BaP) in bread by gas chromatography-mass spectrometry single quadrupole selected ion monitoring (GC/MS-SQ-SIM). Sample preparation includes: extraction of BaP into acetone followed by cleanup with dispersive solid phase extraction. The use of spiked samples for constructing the calibration curve substantially reduced adverse matrix-related effects. The average recovery of BaP at 6 concentration levels was in range of 95-120%. The method was proved to be reproducible with relative standard deviation less than 14.5% for all of the concentration levels. The limit of detection and limit of quantification were 0.3 ng/g and 0.5 ng/g, respectively. Correlation coefficient of 0.997 was obtained for spiked calibration standards over the concentration range of 0.5-20 ng/g. To the best of our knowledge, this is the first time that a QuEChERS method is used for the analysis of BaP in breads. The developed method was used for determination of BaP in 29 traditional (Sangak) and industrial (Senan) bread samples collected from Tehran in 2014. These results showed that two Sangak samples were contaminated with BaP. Therefore, a comprehensive survey for monitoring of BaP in Sangak bread samples seems to be needed. This is the first report concerning contamination of bread samples with BaP in Iran.Entities:
Keywords: Benzo [a] pyrene; Gas chromatography-Mass Spectrometry; Iran; Polycyclic aromatic hydrocarbons; QuEChERS; bread samples
Year: 2016 PMID: 27642317 PMCID: PMC5018274
Source DB: PubMed Journal: Iran J Pharm Res ISSN: 1726-6882 Impact factor: 1.696
Quantifier ions and qualifier ions used in the selected ion-monitoring of BaP and Anthracene-d10 by gas chromatography-mass spectrometry
|
|
|
|
|---|---|---|
| BaP | 252 | 253, 250, 126 |
| Anthracene-d10 | 188 | 189, 187, 160 |
Effect of different extraction solvents on the average recoveries percentage (n = 3) and repeatibility (RSD %) of BaP analyzed in bread samples using QuEChERS method and GC-MS
| Extraction solvent | Acetonitrile | Ethylacetate | Acetone |
|---|---|---|---|
|
| 54.96 ± 27.92 | 49.15 ± 3.18 | 111.18 ± 24.08 |
Retention time and calibration data for BaP
|
|
|
|
|
|
|
|---|---|---|---|---|---|
| 0.5-20 | 11.2 | y = 0.070x - 0.003 | 0.997 | 0.3 | 0.5 |
According to wet weight
BaP recoveries ± RSD (%) for homogenized bread samples using the optimized QuEChERS method at three spiking levels (n = 3
|
|
|
|
|
|---|---|---|---|
| Recovery ± RSD (%) | 119.22 ± 0.77 | 119.85 ± 9.3 | 110.5 ± 11.68 |
Incidence, mean, median and maximum levels of BaP in bread samples
|
|
|
|
|
|
|---|---|---|---|---|
| Traditional bread (Sangak) | 66.66 | 1.97 | 2.73 | 3.19 |
| Industrial bread (Senan) | ND | - | - | - |
Not detected
Figure 1.GC-MS chromatogram of BaP in industrial bread sample
Figure 2GC-MS chromatogram of BaP in Sangak bread sample
Comparison of the proposed QuEChERS method with other methods for extraction and determination of BaP in bread
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ahmed | Soxhlet apparatus | GC-FID | - | - | - | - | - | 82 | 6.7 | > 400 |
| (16) |
| Rey-Salgueiro | solid–liquid extraction (SLE) | (LC-FD) | 0.02 | 0.07 | 0.02-40 | - | ≥0.999 | 103 | 5 | >40 |
| (14) |
| Al-Rashdan | Soxhlet apparatus | GC-MS | 0.1 | 0.3 | 100– | d-PAHs | >0.995 | 82.39 | 4.99 | >175 | hexane | (15) |
| Orecchio and Papuzza | Soxhlet | GC-MS | 0.015 | 0.05 | 100–2000 mg/l) | d-PAHs | 95 | 7-25 | >80 | pentane | (13) | |
| Ciecierska and Obiedziński | GPC | HPLC-FLD/DAD and Confirmation by GC/MS | 0.12 | 0.24 | 1-50 | - | 0.999 | 106 | 5.1 | >150 | hexane/acetone, | (11) |
| Eslamizad | The proposed method | GC-MS | 0.3 | 0.5 | 0.5-20 | d-PAHs | 0.997 | 114.7 | <14.5 | 10 | Acetone | This study |
Liquid-phase volume
Dynamic linear ranges