Literature DB >> 27640611

Effectiveness of Global, Low-Degree Polynomial Transformations for GCxGC Data Alignment.

Davis W Rempe1, Stephen E Reichenbach1,2, Qingping Tao2, Chiara Cordero3, Wayne E Rathbun4, Cláudia Alcaraz Zini5.   

Abstract

As columns age and differ between systems, retention times for comprehensive two-dimensional gas chromatography (GCxGC) may vary between runs. To properly analyze GCxGC chromatograms, it often is desirable to align the retention times of chromatographic features, such as analyte peaks, between chromatograms. Previous work by the authors has shown that global, low-degree polynomial transformation functions, namely affine, second-degree polynomial, and third-degree polynomial, are effective for aligning pairs of two-dimensional chromatograms acquired with dual second columns and detectors (GC×2GC). This work assesses the experimental performance of these global methods on more general GCxGC chromatogram pairs and compares their performance to that of a recent, robust, local alignment algorithm for GCxGC data [ Gros Anal. Chem. 2012 , 84 , 9033 ]. Measuring performance with the root-mean-square (RMS) residual differences in retention times for matched peaks suggests that global, low-degree polynomial transformations outperform the local algorithm given a sufficiently large set of alignment points, and are able to improve misalignment by over 95% based on a lower-bound benchmark of inherent variability. However, with small sets of alignment points, the local method demonstrated lower error rates (although with greater computational overhead). For GCxGC chromatogram pairs with only slight initial misalignment, none of the global or local methods performed well. In some cases with initial misalignment near the inherent variability of the system, these methods worsened alignment, suggesting that it may be better not to perform alignment in such cases.

Year:  2016        PMID: 27640611     DOI: 10.1021/acs.analchem.6b02254

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Coherent Point Drift Peak Alignment Algorithms Using Distance and Similarity Measures for Two-Dimensional Gas Chromatography Mass Spectrometry Data.

Authors:  Zeyu Li; Seongho Kim; Sikai Zhong; Zichun Zhong; Ikuko Kato; Xiang Zhang
Journal:  J Chemom       Date:  2020-03-28       Impact factor: 2.467

2.  Untargeted/Targeted 2D Gas Chromatography/Mass Spectrometry Detection of the Total Volatile Tea Metabolome.

Authors:  Joshua Morimoto; Marta Cialiè Rosso; Nicole Kfoury; Carlo Bicchi; Chiara Cordero; Albert Robbat
Journal:  Molecules       Date:  2019-10-18       Impact factor: 4.411

3.  Automating and Extending Comprehensive Two-Dimensional Gas Chromatography Data Processing by Interfacing Open-Source and Commercial Software.

Authors:  Michael J Wilde; Bo Zhao; Rebecca L Cordell; Wadah Ibrahim; Amisha Singapuri; Neil J Greening; Chris E Brightling; Salman Siddiqui; Paul S Monks; Robert C Free
Journal:  Anal Chem       Date:  2020-10-09       Impact factor: 6.986

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.