Literature DB >> 2763810

Recording pattern reversal visual evoked response with the scanning laser ophthalmoscope.

O Katsumi1, G T Timberlake, T Hirose, F J Van de Velde, H Sakaue.   

Abstract

We recorded visual evoked responses (VERs) to alternating, checkerboard pattern stimuli using the scanning laser ophthalmoscope (SLO). Retinal position and focus of checkerboard stimuli were monitored on the SLO video monitor throughout testing. Checkerboard size, check size, and retinal positions were varied. Consistent with other, well-established pattern reversal techniques, the SLO method produced: 1) reliable VERs with amplitudes of 2 to 10 microvolts, 2) maximum amplitudes at an intermediate check size for a fixed overall pattern size, and 3) variations in VER amplitude depending on stimulus retinal position relative to the fovea. Hence, the SLO-VER technique would be useful for clinical VER measurements when precise retinal stimulus position and focus are desired.

Mesh:

Year:  1989        PMID: 2763810     DOI: 10.1111/j.1755-3768.1989.tb01865.x

Source DB:  PubMed          Journal:  Acta Ophthalmol (Copenh)        ISSN: 0001-639X


  6 in total

1.  Quadrant pattern ERG with SLO stimulation in normals and glaucoma patients.

Authors:  F Horn; C Mardin; M Korth; P Martus
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-08       Impact factor: 3.117

2.  Differences between pattern-evoked electroretinograms obtained by a scanning laser ophthalmoscope and by a mechanical mirror system.

Authors:  F Horn; M Korth
Journal:  Doc Ophthalmol       Date:  1994       Impact factor: 2.379

3.  Colored focal visual evoked potentials by cathode ray tube versus scanning laser ophthalmoscope.

Authors:  F Rigaudière; J F Le Gargasson; J E Guez; Y Grall
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

4.  Contribution of scanning laser ophthalmoscopy to the functional investigation of subjects with macular holes.

Authors:  J F Le Gargasson; F Rigaudiere; J E Guez; A Gaudric; Y Grall
Journal:  Doc Ophthalmol       Date:  1994       Impact factor: 2.379

5.  Clinical investigation of an infrared digital scanning laser ophthalmoscope.

Authors:  A Manivannan; J N Kirkpatrick; P F Sharp; J V Forrester
Journal:  Br J Ophthalmol       Date:  1994-02       Impact factor: 4.638

6.  Focal visual evoked potentials generated by scanning laser ophthalmoscope in patients with age-related macular degeneration treated by perifoveal photocoagulation.

Authors:  S Y Cohen; J F Le Gargasson; J E Guez; F Rigaudière; G J Coscas; Y Grall
Journal:  Doc Ophthalmol       Date:  1994       Impact factor: 2.379

  6 in total