Magnification effects on distance estimation during robotic suturing.

Daniel D Gruber1, Jason C Massengill2, Shannon V Lamb2, Heather M Barbier2, Christopher J Rosemeyer2, Ernest G Lockrow2, Jerome L Buller3.   

Abstract

We aimed to understand the impact of magnification on distance estimation during robotic suturing. Twenty subjects estimated the lengths of various sutures externally, in plain sight, to validate their ability to measure distances. They then robotically repaired a 3-cm cystotomy, suturing 10 mm above and below the incision and 10 mm on either side of the incision. The bladder was removed and distances measured. A total of 20 surgeons were analyzed: 7 residents, 8 fellows, and 5 staff. Specialties comprised four urologists, eight general gynecologists, two urogynecologists, three gynecologic oncologists, and three reproductive endocrinologists. The mean estimation for external suture length was not significant at 10 mm: mean = 9.6 (±3.2) mm (p = 0.59). When comparing these data sets, the externally visualized 10-mm suture versus the suture-to-suture and the suture-to-incision distances were both significantly different (p = 0.002 and p < 0.001, respectively). The mean distance between each suture was 6.5 (±1.8) mm, which was significantly different from the 10-mm goal (p < 0.001, 95 % confidence interval (CI) [-4.4,-2.6]). The mean distance from the suture to the incision was 4.1 (±1.0) mm, which was also statistically significantly different from the goal (p < 0.001, 95 % CI [-6.3,-5.4]). Surgical experience was negatively associated with suture-to-incision distance (r s = -0.53, p = 0.016). Inter-suture distance was also negatively associated with experience (r s = -0.30, p = 0.22), though not statistically significant. In vivo distances are significantly underestimated during robotic suture placement. Interestingly, the most experienced surgeons had the worst distance estimation from the incision to the suture.

Keywords:  Magnification; Motion scaling; Robotic surgery; Suturing; Suturing accuracy

Year:  2014        PMID: 27637683     DOI: 10.1007/s11701-014-0456-1

Source DB:  PubMed          Journal:  J Robot Surg        ISSN: 1863-2483


  2 in total

1.  Optimizing motion scaling and magnification in robotic surgery.

Authors:  Ryan Cassilly; Michael D Diodato; Michael Bottros; Ralph J Damiano
Journal:  Surgery       Date:  2004-08       Impact factor: 3.982

Review 2.  Outcome of endodontic surgery: a meta-analysis of the literature--Part 2: Comparison of endodontic microsurgical techniques with and without the use of higher magnification.

Authors:  Frank C Setzer; Meetu R Kohli; Sweta B Shah; Bekir Karabucak; Syngcuk Kim
Journal:  J Endod       Date:  2011-11-21       Impact factor: 4.171

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.