Literature DB >> 27637242

The head butler with design modification: a useful mountable shelf for the operating table in robotic surgery.

Teresa Tam1, Gerald Harkins2, Stephanie Estes2,3.   

Abstract

The 'head butler' or 'iron maiden', as it is sometimes referred to, is a mountable shelf that is attached to the main operating room table using stirrup clamps or brackets. It provides an elevated flat surface, which protects the patient's face and chest from inadvertent trauma of robotic arms, instruments and camera while also serving as a platform for placement of instrumentation that minimizes handoffs to improve workflow. Its canted design also prevents slippage of instruments off the operating field during steep Trendelenburg positioning. This operating room equipment was designed to improve efficiency in an operating room set-up while ensuring safety during patient positioning when performing robotic procedures. A modification of the original Head Butler(®) (Tri-Medical Corporation, Portland, OR, USA) is presented here which improves upon the design by avoiding brachial plexus nerve injury to the patient due to pressure from the uprights pressing on the patient's shoulders during use.

Entities:  

Year:  2013        PMID: 27637242     DOI: 10.1007/s11701-013-0409-0

Source DB:  PubMed          Journal:  J Robot Surg        ISSN: 1863-2483


  6 in total

Review 1.  Robotic gynecologic surgery.

Authors:  Anthony G Visco; Arnold P Advincula
Journal:  Obstet Gynecol       Date:  2008-12       Impact factor: 7.661

Review 2.  Laparoscopic positioning and nerve injuries.

Authors:  J Cory Barnett; William W Hurd; Robert M Rogers; Ned L Williams; Scott A Shapiro
Journal:  J Minim Invasive Gynecol       Date:  2007 Sep-Oct       Impact factor: 4.137

3.  The prevention of injuries of the brachial plexus secondary to malposition of the patient during surgery.

Authors:  D E Cooper; R S Jenkins; L Bready; C A Rockwood
Journal:  Clin Orthop Relat Res       Date:  1988-03       Impact factor: 4.176

Review 4.  Brachial plexus injury after laparoscopic and robotic surgery.

Authors:  David Shveiky; John N Aseff; Cheryl B Iglesia
Journal:  J Minim Invasive Gynecol       Date:  2010 Jul-Aug       Impact factor: 4.137

5.  Robot-assisted laparoscopic myomectomy versus abdominal myomectomy: a comparison of short-term surgical outcomes and immediate costs.

Authors:  Arnold P Advincula; Xiao Xu; Suntrea Goudeau; Scott B Ransom
Journal:  J Minim Invasive Gynecol       Date:  2007 Nov-Dec       Impact factor: 4.137

6.  A case of bilateral brachial plexus palsy due to shoulder braces.

Authors:  Christopher D Kent; Frederick W Cheney
Journal:  J Clin Anesth       Date:  2007-09       Impact factor: 9.452

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.