Literature DB >> 27635772

Muscle Near-Infrared Spectroscopy Signals versus Venous Blood Hemoglobin Oxygen Saturation in Skeletal Muscle.

Y I Sun1, Brian S Ferguson, Mmatthew J Rogatzki, James R McDonald, L Bruce Gladden.   

Abstract

PURPOSE: The study aimed to examine the relationship between near-infrared spectroscopy (NIRS) signals and venous hemoglobin oxygen saturation (O2Hb%) and venous oxygen concentration (CvO2).
METHODS: Gastrocnemius muscles (GS) in six dogs were surgically isolated and pump perfused. NIRS signals were recorded, and venous blood samples were collected at constant flow rates (control flow, high flow, and low flow) at rest as well as during electrically stimulated tetanic muscle contractions at rates of one contraction per 2 s (1/2 s) and two contractions per 3 s (2/3 s). Similar data were also collected at three different inspired O2 percentages (12%, 21%, and 100%) with constant blood flow.
RESULTS: Complete data from five animals were analyzed; all data from one animal were deleted because of erratic oxy-NIRS signals. Venous O2Hb% ranged from 7.6% to 97.5% across the various experimental conditions. After the NIRS signals were normalized to the physiological range, a high linear correlation was seen between the deoxygenated heme signal (HHbMb%) and the venous O2Hb% (R = 0.92 ± 0.05), between the oxygenated heme signal (HbMbO2%) and the venous O2Hb% (R = 0.92 ± 0.03), between the HHbMb% and the CvO2 (R = 0.89 ± 0.06), and between the HbMbO2% and the CvO2 (R = 0.90 ± 0.05). The overall relationships between HHbMb%, HbMbO2%, and venous O2Hb% as well as between HHbMb%, HbMbO2%, and CvO2 were also linear and highly correlated with R values ranging from 0.81 to 0.90.
CONCLUSION: In this controlled canine muscle model, NIRS signals are highly correlated with venous O2Hb% and CvO2 across a wide range of physiological conditions. The practical application of our results is that for an individual muscle or perhaps muscle group, normalized NIRS HHbMb and HbMbO2 signals accurately reflect the mean venous O2 saturation of the interrogated muscle tissue.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27635772     DOI: 10.1249/MSS.0000000000001001

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  6 in total

1.  Near-infrared diffuse correlation spectroscopy tracks changes in oxygen delivery and utilization during exercise with and without isolated arterial compression.

Authors:  Wesley J Tucker; Ryan Rosenberry; Darian Trojacek; Belinda Sanchez; Robert F Bentley; Mark J Haykowsky; Fenghua Tian; Michael D Nelson
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2019-11-20       Impact factor: 3.619

2.  Studies into the determinants of skeletal muscle oxygen consumption: novel insight from near-infrared diffuse correlation spectroscopy.

Authors:  Wesley J Tucker; Ryan Rosenberry; Darian Trojacek; Houda H Chamseddine; Carrie A Arena-Marshall; Ye Zhu; Jing Wang; J Mikhail Kellawan; Mark J Haykowsky; Fenghua Tian; Michael D Nelson
Journal:  J Physiol       Date:  2019-04-29       Impact factor: 5.182

3.  Blood volume versus deoxygenated NIRS signal: computational analysis of the effects muscle O2 delivery and blood volume on the NIRS signals.

Authors:  B Koirala; A Concas; Yi Sun; L B Gladden; N Lai
Journal:  J Appl Physiol (1985)       Date:  2021-09-16

4.  Greater V˙O2peak is correlated with greater skeletal muscle deoxygenation amplitude and hemoglobin concentration within individual muscles during ramp-incremental cycle exercise.

Authors:  Dai Okushima; David C Poole; Thomas J Barstow; Harry B Rossiter; Narihiko Kondo; T Scott Bowen; Tatsuro Amano; Shunsaku Koga
Journal:  Physiol Rep       Date:  2016-12

5.  Lactate production without hypoxia in skeletal muscle during electrical cycling: Crossover study of femoral venous-arterial differences in healthy volunteers.

Authors:  Jan Gojda; Petr Waldauf; Natália Hrušková; Barbora Blahutová; Adéla Krajčová; Tomáš Urban; Petr Tůma; Kamila Řasová; František Duška
Journal:  PLoS One       Date:  2019-03-01       Impact factor: 3.240

6.  Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor.

Authors:  Andri Feldmann; Roger Schmitz; Daniel Erlacher
Journal:  J Biomed Opt       Date:  2019-11       Impact factor: 3.170

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.