Abstract
The authors describe a technique to qualitatively analyze the posterior segment during cataract surgery using intraoperative optical coherence tomography (iOCT). Macular iOCT can be done before and after intraocular lens implantation after the media is rendered clear following phacoemulsification. A handheld irrigating planoconcave contact lens is placed over the cornea with the operating microscope in retroillumination mode. After focusing the microscope and upon getting a clear view of the posterior segment, iOCT is switched on, centered at the macula, and focused. This technique enables the surgeon to intraoperatively analyze and document the macular morphology and vitreoretinal interface. Potential uses of this technique include intraoperative decision-making regarding concurrent use of anti-vascular endothelial growth factor agents or steroids in cases with dense cataracts where preoperative OCT is difficult. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:846-847.]. Copyright 2016, SLACK Incorporated.Entities:
Mesh:
Year: 2016 PMID: 27631481 DOI: 10.3928/23258160-20160901-08
Source DB: PubMed Journal: Ophthalmic Surg Lasers Imaging Retina ISSN: 2325-8160 Impact factor: 1.300