A Pseudo-Outbreak of Pseudomonas putida and Stenotrophomonas maltophilia in a Bronchoscopy Unit.

Maribel Botana-Rial1, Virginia Leiro-Fernández, Manuel Núñez-Delgado, Maximiliano Álvarez-Fernández, Susana Otero-Fernández, Helena Bello-Rodríguez, Carlos Vilariño-Pombo, Alberto Fernández-Villar.   

Abstract

BACKGROUND: Endoscopes represent the medical devices most commonly linked to health care-associated outbreaks and pseudo-outbreaks. Most of the recent outbreaks and pseudo-outbreaks have resulted from contaminated automated endoscope reprocessors (AER) or the use of damaged or malfunctioning bronchoscopes or contaminated equipment.
OBJECTIVES: We investigated a pseudo-outbreak of Pseudomonas putida and Stenotrophomonas maltophilia recovered from bronchial washing (BW) specimens obtained during bronchoscopy in a bronchoscopy unit.
METHODS: Samples were obtained from environmental surfaces in the endoscopy suite, bronchoscopes, and bronchoscopic dispensable material, and specimens of cleaning solutions, cleaning brushes, the AER, and the ultrasound system were sent for bacterial culture. Medical records were reviewed to identify possible infections after a bronchoscopy.
RESULTS: P. putida and S. maltophilia were isolated from BW samples of 39 patients. The bronchoscopy models Olympus BF-1T160 and BF-160 were contaminated. Both bronchoscopes and other contaminated material (cleaning brushes, diluted cleaning solutions, and the sink) were isolated, but new cases continued to appear. The AER was recently installed, and new connections were used for the water lines and new tubes were connected to the AER. Initially, specimens were obtained from the external circuits and the internal walls of the AER. Finally, cultures were made from the filters on the water lines, and growth of P. putida and S. maltophilia was found. The investigation revealed that the BW specimens were contaminated because sterile saline was injected by means of the biopsy port of the bronchoscope and was recovered through the same channel by means of the proximal suction port. No patients developed clinical signs or symptoms of infection, but the positive cultures did lead to treatment of 21 patients.
CONCLUSIONS: We described a pseudo-outbreak related to a contaminated bronchoscope because of inadequate installation of the AER for used new water lines and because the new tubes were connected to the AER. The antibacterial filters of the AER used tap water, and this may have contained low levels of microorganisms. No serious clinical complications derived from this pseudo-outbreak.
© 2016 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2016        PMID: 27627819     DOI: 10.1159/000449137

Source DB:  PubMed          Journal:  Respiration        ISSN: 0025-7931            Impact factor:   3.580


  5 in total

1.  The Cost of Flexible Bronchoscopes: A Systematic Review and Meta-analysis.

Authors:  Carina Østervig Andersen; Helena Travis; Emilie Dehlholm-Lambertsen; Rasmus Russell; Emmelie Ploug Jørgensen
Journal:  Pharmacoecon Open       Date:  2022-08-22

2.  Molecular Epidemiology, Antibiotic Resistance, and Virulence Traits of Stenotrophomonas maltophilia Strains Associated With an Outbreak in a Mexican Tertiary Care Hospital.

Authors:  Ariadnna Cruz-Córdova; Jetsi Mancilla-Rojano; Víctor M Luna-Pineda; Gerardo Escalona-Venegas; Vicenta Cázares-Domínguez; Christopher Ormsby; Isabel Franco-Hernández; Sergio Zavala-Vega; Mónica Andrés Hernández; Marisol Medina-Pelcastre; Israel Parra-Ortega; Daniela De la Rosa-Zamboni; Sara A Ochoa; Juan Xicohtencatl-Cortes
Journal:  Front Cell Infect Microbiol       Date:  2020-02-18       Impact factor: 5.293

3.  A systematic review and cost effectiveness analysis of reusable vs. single-use flexible bronchoscopes.

Authors:  J M Mouritsen; L Ehlers; J Kovaleva; I Ahmad; K El-Boghdadly
Journal:  Anaesthesia       Date:  2019-11-08       Impact factor: 6.955

Review 4.  Medical Device Sterilization and Reprocessing in the Era of Multidrug-Resistant (MDR) Bacteria: Issues and Regulatory Concepts.

Authors:  Jonathan Josephs-Spaulding; Om V Singh
Journal:  Front Med Technol       Date:  2021-02-10

5.  Cluster of S. maltophilia among patients with respiratory tract infections at an intensive care unit.

Authors:  Maria Gideskog; Jenny Welander; Åsa Melhus
Journal:  Infect Prev Pract       Date:  2020-09-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.