Biomechanical evaluation of novel ultrasound-activated bioresorbable pins for the treatment of osteochondral fractures compared to established methods.

Benjamin Kienast1, Hellal Mohsen1, Robert Wendlandt1, Nils Reimers1, Arndt P Schulz1, Hinrich Heuer1, Justus Gille1, Hanjo Neumann1.   

Abstract

BACKGROUND: Osteochondral injuries often lead to osteoarthritis of the affected joint. All established systems for refixation of osteochondral defects show certain disadvantages. To address the problem of reduced stability in resorbable implants, ultrasound-activated pins were developed. By ultrasound-activated melting of the tip of these implants, a more secure anchoring is assumed.
MATERIALS AND METHODS: The aim of the study was to investigate if ultrasound-activated pins can provide secure fixation of osteochondral fragments compared to screws and conventional resorbable pins. In a biomechanical laboratory setting, osteochondral fragments of the medial femoral condyle of sheep were refixated with ultrasound-activated pins [US fused poly(L-lactide-co-D,L-lactide) (PLDLLA) pins], polydioxanone (PDA) pins and conventional titanium screws. Anchoring forces of the different fixation methods were examined, registered and compared concerning shear force and tensile force.
RESULTS: Concerning the pull out test, the US fused PLDLLA pins and titanium screws (~122 N and ~203 N) showed comparable good results, while the PDA pins showed significantly lower anchoring forces (~18 N). Examination of shear forces showed a significantly higher anchoring of the screws (~248 N) than the US fused PLDLLA pins (~218 N). Nevertheless, the US fused PLDLLA pins could significantly outperform the PDA pins (~68 N) concerning shear forces.
CONCLUSION: The US fused PLDLLA pins demonstrated a comparable anchorage to the fixation with screws, but were free from the disadvantages of metal implants, i.e. the need for implant removal. The PDA pin application showed inferior biomechanical properties.

Entities:  

Keywords:  biomechanics; fracture; osteochondral; polymer; refixation; ultrasound-activated

Mesh:

Substances:

Year:  2017        PMID: 27626763     DOI: 10.1515/bmt-2016-0041

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  1 in total

1.  Biocompatibility Analyses of HF-Passivated Magnesium Screws for Guided Bone Regeneration (GBR).

Authors:  Ole Jung; Bernhard Hesse; Sanja Stojanovic; Christian Seim; Timm Weitkamp; Milijana Batinic; Oliver Goerke; Željka Perić Kačarević; Patrick Rider; Stevo Najman; Mike Barbeck
Journal:  Int J Mol Sci       Date:  2021-11-22       Impact factor: 5.923

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.