Abstract

PURPOSE: To assess screw divergence when inserting an interference screw for a bone-patellar tendon-bone graft using an outside-in technique with a retrograde drill to create the femoral tunnel.
METHODS: Ten cadaver specimens underwent anterior cruciate ligament reconstruction with a bone-patellar tendon-bone autograft, with 23-mm-deep tunnels created by a retrograde drill outside-in technique. Drilling angles were based on a previous study that established the optimal angles to recreate the anterior cruciate ligament footprint. To ensure that screw insertion angles matched the angle of socket drilling, a marking pen was used to transpose 2 lines on the skin of the anterior knee corresponding to the drill in both the coronal and axial planes with the knee held at 90° of flexion. The femoral-sided bone plug was affixed with a 7 × 23 mm interference screw through an anteromedial portal. Computed tomography scans were used to calculate coronal and sagittal screw-tunnel divergence.
RESULTS: The median screw divergence in the coronal plane was 2.79°, with a range of 1.1° to 17.2°. Of 10 specimens, 8 had no divergence (0° to 5°), 0 screws were between 5° and 10°, 1 screw was between 10° and 15°, and 1 screw was between 15° and 20°. The 95% confidence interval was 3.73° to 11.69°. No screws had ≥20° of divergence. In the sagittal plane, the median screw divergence was 5.68°, with a range of 1.2° to 18.7°. Five specimens had no divergence (0° to 5°), 3 screws were between 5° and 10°, 0 screws were between 10° and 15°, and 2 screws were between 15° and 20° of divergence. The 95% confidence interval was 3.73° to 11.69°. No screws had ≥20° of divergence.
CONCLUSIONS: The results of this study showed that 80% of screws diverted less than 5° in the coronal plane. In the sagittal plane, only 50% of screws were found to have divergence of 5° or less. No screw in either plane had divergence of greater than or equal to 20°. CLINICAL RELEVANCE: When using a retrograde drill, a skin marking technique is a useful aid in placing interference screws with acceptable angles of divergence when using an inside-out technique.
Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27625004     DOI: 10.1016/j.arthro.2016.07.009

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  1 in total

1.  Hyperflexion and Femoral Interference Screw Insertion in ACL Reconstruction.

Authors:  Mark E Steiner; David Wing; Kempland C Walley; Ohan Manoukian; Miguel Perez-Viloria; Stephen Okajima; Ara Nazarian
Journal:  Orthop J Sports Med       Date:  2018-08-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.