Literature DB >> 27624474

Non-gadolinium dynamic angiography of the neurovasculature using arterial spin labeling MRI: preliminary experience in children.

Houchun H Hu1, Amber L Pokorney2, Niccolo Stefani3, Jonathan M Chia4, Jeffrey H Miller2.   

Abstract

OBJECTIVE: We demonstrate the potential clinical utility of a 4D non-gadolinium dynamic angiography technique based on arterial spin-labeling called contrast inherent inflow enhanced multi-phase angiography (CINEMA) in pediatric patients.
MATERIALS AND METHODS: CINEMA was qualitatively compared to conventional time-of-flight (TOF) angiography in a cohort of 31 pediatric patients at 3 Tesla.
RESULTS: CINEMA data were successfully acquired and reconstructed in all patients with no image artifacts. There were no cases where CINEMA was rated inferior to TOF in depicting intracranial vessel conspicuity. In 19 cases, CINEMA was rated equivalent to TOF and in the 12 remaining cases CINEMA was rated superior to TOF.
CONCLUSION: There is a steadily rising concern in adults and children over the potential effects of intracranial deposition of gadolinium. CINEMA is therefore a viable alternative in dynamic neurovascular imaging.

Entities:  

Keywords:  Dynamic arterial spin labeling; Intracranial vasculature; Non-contrast-enhanced MR angiography; Pediatric

Mesh:

Substances:

Year:  2016        PMID: 27624474     DOI: 10.1007/s10334-016-0589-5

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  12 in total

Review 1.  Non-contrast enhanced MR angiography: established techniques.

Authors:  Mitsue Miyazaki; Masaaki Akahane
Journal:  J Magn Reson Imaging       Date:  2012-01       Impact factor: 4.813

2.  The 39 steps: evading error and deciphering the secrets for accurate dynamic susceptibility contrast MRI.

Authors:  Lisa Willats; Fernando Calamante
Journal:  NMR Biomed       Date:  2012-07-11       Impact factor: 4.044

3.  Compressed sensing in dynamic MRI.

Authors:  Urs Gamper; Peter Boesiger; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

Review 4.  Time-resolved angiography: Past, present, and future.

Authors:  Thomas M Grist; Charles A Mistretta; Charles M Strother; Patrick A Turski
Journal:  J Magn Reson Imaging       Date:  2012-05-07       Impact factor: 4.813

5.  [Non-contrast time-resolved magnetic resonance angiography combining high resolution multiple phase echo planar imaging based signal targeting and alternating radiofrequency contrast inherent inflow enhanced multi phase angiography combining spatial resolution echo planar imaging based signal targeting and alternating radiofrequency in intracranial arteries].

Authors:  Masanobu Nakamura; Masami Yoneyama; Takashi Tabuchi; Atsushi Takemura; Makoto Obara; Seishi Sawano
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2012

Review 6.  Non-contrast enhanced MR angiography: physical principles.

Authors:  Andrew J Wheaton; Mitsue Miyazaki
Journal:  J Magn Reson Imaging       Date:  2012-08       Impact factor: 4.813

7.  Improving non-contrast-enhanced steady-state free precession angiography with compressed sensing.

Authors:  Tolga Cukur; Michael Lustig; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

8.  Intracranial dural arteriovenous fistulas: evaluation with 3-T four-dimensional MR angiography using arterial spin labeling.

Authors:  Yasuhiko Iryo; Toshinori Hirai; Yutaka Kai; Masanobu Nakamura; Yoshinori Shigematsu; Mika Kitajima; Minako Azuma; Masanori Komi; Kosuke Morita; Yasuyuki Yamashita
Journal:  Radiology       Date:  2013-11-21       Impact factor: 11.105

Review 9.  Perfusion magnetic resonance imaging: a comprehensive update on principles and techniques.

Authors:  Geon-Ho Jahng; Ka-Loh Li; Leif Ostergaard; Fernando Calamante
Journal:  Korean J Radiol       Date:  2014-09-12       Impact factor: 3.500

10.  Evaluation of Intracranial Vasculatures in Healthy Subjects with Arterial-Spin-Labeling-Based 4D-MR Angiography at 3T.

Authors:  Yasuhiko Iryo; Toshinori Hirai; Masanobu Nakamura; Machiko Tateishi; Eri Hayashida; Minako Azuma; Shinichiro Nishimura; Mika Kitajima; Yasuyuki Yamashita
Journal:  Magn Reson Med Sci       Date:  2015-12-22       Impact factor: 2.471

View more
  3 in total

Review 1.  Intracranial 3D and 4D MR Angiography Using Arterial Spin Labeling: Technical Considerations.

Authors:  Yuriko Suzuki; Noriyuki Fujima; Matthias J P van Osch
Journal:  Magn Reson Med Sci       Date:  2019-11-22       Impact factor: 2.471

Review 2.  Pseudocontinuous Arterial Spin Labeling: Clinical Applications and Usefulness in Head and Neck Entities.

Authors:  Fumine Tanaka; Maki Umino; Masayuki Maeda; Ryohei Nakayama; Katsuhiro Inoue; Ryota Kogue; Makoto Obara; Hajime Sakuma
Journal:  Cancers (Basel)       Date:  2022-08-11       Impact factor: 6.575

Review 3.  Recent Technical Developments in ASL: A Review of the State of the Art.

Authors:  Luis Hernandez-Garcia; Verónica Aramendía-Vidaurreta; Divya S Bolar; Weiying Dai; Maria A Fernández-Seara; Jia Guo; Ananth J Madhuranthakam; Henk Mutsaerts; Jan Petr; Qin Qin; Jonas Schollenberger; Yuriko Suzuki; Manuel Taso; David L Thomas; Matthias J P van Osch; Joseph Woods; Moss Y Zhao; Lirong Yan; Ze Wang; Li Zhao; Thomas W Okell
Journal:  Magn Reson Med       Date:  2022-08-19       Impact factor: 3.737

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.