Impact of prosthesis-patient mismatch on early haemodynamic status after aortic valve replacement.

Michel Kindo1, Tam Hoang Minh2, Stéphanie Perrier2, Hélène Petit-Eisenmann3, Jonathan Bentz2, Mircea Cristinar4, Gharib Ajob4, Olivier Collange4, Jean-Philippe Mazzucotelli2.   

Abstract

OBJECTIVES: Prosthesis-patient mismatch (PPM) has been reported to impact early haemodynamic status and early mortality after prosthetic aortic valve replacement (AVR) in patients with aortic stenosis (AS). The aim of this study was to assess the impact of PMM on early haemodynamic status after AVR using vasoactive-inotropic dependency index (VDI), postoperative pressures and end-organ perfusion.
METHODS: A total of 183 patients with AS were included in this prospective cohort study, and underwent elective AVR with or without combined coronary artery bypass graft surgery. PPM was defined as a projected indexed effective orifice area of ≤0.85 cm2/m2, and was present in 27.9% of the patients. The primary end-point was the VDI [VDI = vasoactive-inotropic score/mean arterial pressure] measured upon admission to the intensive care unit (POD0) and on the morning of the first postoperative day (POD1). The secondary end-points were the following: mean left atrial pressure, mean central venous pressure, fluid balance, brain natriuretic peptide, troponin I, glomerular filtration rate and lactate levels on POD0 and POD1.
RESULTS: No significant differences in VDI were observed between the no PPM and PPM groups on POD0 (0.08 ± 0.48 vs 0.05 ± 0.13, respectively, P = 0.622) or on POD1 (0.09 ± 0.40 vs 0.06 ± 0.13, respectively; P = 0.583). The mean arterial pressure, mean left atrial pressure, central venous pressure, troponin I, glomerular filtration rate and lactate levels did not differ between the two groups on POD0 and POD1, as well as fluid balance and brain natriuretic peptide on POD1.
CONCLUSIONS: PPM is not associated with early haemodynamic status impairment and end-organ perfusion after AVR. CLINICAL TRIAL NUMBER: ClinicalTrials.gov number, NCT00699673.
© The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic stenosis; Cardiac surgery; Prosthetic heart valves; Quality and outcomes of care; Valve disease surgery

Mesh:

Substances:

Year:  2016        PMID: 27624355     DOI: 10.1093/icvts/ivw303

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  1 in total

1.  Early outcomes of patient-prosthesis mismatch following aortic valve replacement.

Authors:  Serik Aitaliyev; Egle Rumbinaitė; Karolina Mėlinytė-Ankudavičė; Rokas Nekrošius; Vytenis Keturakis; Rimantas Benetis
Journal:  Perfusion       Date:  2021-06-03       Impact factor: 1.581

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.