Literature DB >> 27616447

Efficient nonarterialized mouse liver transplantation using 3-dimensional-printed instruments.

Graziano Oldani1,2, Stéphanie Lacotte1, Lorenzo A Orci1,2, Vaihere Delaune1,2, Florence Slits1, Quentin Gex1, Philippe Morel1,2, Laura Rubbia-Brandt2,3, Christian Toso1,2.   

Abstract

Because of the wide availability of genetically modified animals, mouse orthotopic liver transplantation is often preferred over rat liver transplantation. We present a simplified mouse liver transplantation technique and compare transplantation outcomes with versus without hepatic artery anastomosis. Instruments for liver implantation were designed and printed with a 3-dimensional (3D) printer. The suprahepatic vena cava anastomosis was performed with a 10-0 running suture. The vena porta and infrahepatic vena cava were joined on extraluminal cuffs, using the 3D-printed device for spatial alignment and stabilization. The hepatic artery was reconstructed in half of the recipients using intraluminal stents. Liver function tests (3, 7, and 28 days) and histology (7 and 28 days) were assessed after transplantation. We performed 22 consecutive syngeneic C57BL/6 mouse orthotopic liver transplantations. The median portal clamping time was 12.5 ± 1.5 minutes. The survival rate at 4 weeks was 100% for both arterialized and nonarterialized recipients (n = 7, 4 recipients of each group being killed for early histology at day 7). Liver function tests at 3, 7, and 28 days were similar between arterialized versus nonarterialized groups. Liver parenchyma demonstrated only irrelevant abnormalities in both groups. The proposed device allows for a shorter clamping time compared with the published literature. Using this technique, the artery does not need to be anastomosed, with no impact on graft and recipient outcomes. The device is available for 3D printing. Liver Transplantation 22 1688-1696 2016 AASLD.
© 2016 by the American Association for the Study of Liver Diseases.

Entities:  

Mesh:

Year:  2016        PMID: 27616447     DOI: 10.1002/lt.24637

Source DB:  PubMed          Journal:  Liver Transpl        ISSN: 1527-6465            Impact factor:   5.799


  3 in total

1.  Effect of the Combination of Everolimus and Mesenchymal Stromal Cells on Regulatory T Cells Levels and in a Liver Transplant Rejection Model in Rats.

Authors:  Morgan Vandermeulen; Pauline Erpicum; Noella Bletard; Laurence Poma; François Jouret; Olivier Detry
Journal:  Front Immunol       Date:  2022-06-10       Impact factor: 8.786

2.  The impact of short-term machine perfusion on the risk of cancer recurrence after rat liver transplantation with donors after circulatory death.

Authors:  Graziano Oldani; Andrea Peloso; Florence Slits; Quentin Gex; Vaihere Delaune; Lorenzo A Orci; Yohan van de Looij; Didier J Colin; Stéphane Germain; Claudio de Vito; Laura Rubbia-Brandt; Stéphanie Lacotte; Christian Toso
Journal:  PLoS One       Date:  2019-11-25       Impact factor: 3.240

Review 3.  Details determining the success in establishing a mouse orthotopic liver transplantation model.

Authors:  Ting Li; Zheng Hu; Lei Wang; Guo-Yue Lv
Journal:  World J Gastroenterol       Date:  2020-07-21       Impact factor: 5.742

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.