BACKGROUND: This single-center retrospective study assessed the variation of left ventricular ejection fraction (LVEF) after transapical transcatheter aortic valve implantation and its effect on survival. We also evaluated the effect of sheath diameter on LVEF.
METHODS: We analyzed data of all consecutive patients who underwent transapical transcatheter aortic valve implantation with the Sapien (Edwards Lifesciences, Irvine, CA) device (and its evolutions) between 2009 and 2015. We analyzed the difference between preoperative LVEF and LVEF at discharge (ΔEF = LVEFpost-op - LVEFpre-op) and considered its interquartile range (±5%) as the cutoff. Patients were divided in three groups: (1) improved LVEF (ΔEF ≥ +5%); (2) unchanged LVEF (ΔEF -5% to +5%), and (3) worsened LVEF (ΔEF ≤ -5%). Survival was evaluated with Kaplan-Meier analysis, and logistic regression multivariable analysis was used to determine independent predictors of LVEF improvement.
RESULTS: Data of 122 patients were analyzed. Patients in the three groups were distributed as follows: (group 1) 27 patients (22.1%), (group 2) 69 (56.6%), and (group 3) 26 (21.3%). The mean ΔEF was 12.7% ± 4.7% in group 1 and -10.8% ± 3.9% in group 3. The ΔEF was more likely to improve in patients with preoperative LVEF of less than 0.35 (p = 0.014). There were no significant differences in survival (p = 0.41), rehospitalization (p = 0.472), and New York Heart Association Functional Classification (p = 0.307) among the groups. The use of the smallest available sheath (18F) was not associated with a significant change of ΔEF.
CONCLUSIONS: LVEF worsened in a small number of patients after transapical transcatheter aortic valve implantation, but this change was not associated with worse postoperative outcomes. Patients with a low LVEF showed better improvement. The progressive reduction of sheath diameter does not have a significant effect on LVEF changes.
Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27614737     DOI: 10.1016/j.athoracsur.2016.06.042

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  2 in total

1.  Transcatheter aortic valve replacement in patients with high aortic anguation.

Authors:  Kai Zhu; Xiao Liu; Jun Li
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

2.  Access options for transcatheter mitral valve implantation in patients with prior surgical bioprosthesis.

Authors:  Laura Besola; Anson Cheung; Jian Ye; Myriam Akodad; Andrew Chatfield; Gnalini Sathananthan; Robert Moss; John Webb
Journal:  Ann Cardiothorac Surg       Date:  2021-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.