The Inter-rater Reliability of Echocardiographic Diastolic Function Evaluation Among Emergency Physician Sonographers.

Turandot Saul1, Nicholas C Avitabile1, Rachel Berkowitz1, Sebastian D Siadecki1, Gabriel Rose1, Mojdeh Toomarian1, Nicole L Kaban1, Nicholas Governatori1, Maria Suprun2.   

Abstract

STUDY
OBJECTIVES: In a patient with dyspnea and suspected CHF, the evaluation of diastolic function involves: tissue Doppler of the mitral annulus and 2) pulsed wave Doppler of the mitral inflow. We aimed to 1) determine the inter-rater reliability for overall diastolic function and 2) evaluate the reliability of the individual Doppler measurements.
METHODS: A convenience sample of adult emergency department patients was prospectively enrolled by 8 EPs who had participated in a 1-hour didactic session. Patients were selected if they had a history of CHF or suspected abnormal diastolic function due to chronic hypertension. Diastolic function was considered to be abnormal if Tissue Doppler of the septal e' was <8 cm/s and if the lateral e' was <10 cm/s. In cases of discordance, the E/e' ratio was calculated with ≤8 considered normal and >8 considered abnormal. A Kappa coefficient. Bland-Altman plot and a fixed effect regression model were used in the analysis.
RESULTS: Thirty-two patients were enrolled, and 3 (9.4%) were excluded due to technical inadequacy. The inter-rater reliability among sonographers for overall interpretation was very good: κ = 0.86 (95% CL [0.67, 1.0]). Based on the Bland-Altman plot, was no consistent bias between readers. There was no evidence to conclude that the readings differed among sonographers: septal e' (p = 0.77), lateral e' (p = 0.89) and E (p = 0.15).
CONCLUSION: EP sonographers obtained similar Doppler measurements for diastolic function evaluation with very good inter-rater reliability for the assessment of overall diastolic function.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  bedside ultrasound; congestive heart failure; echocardiography

Mesh:

Year:  2016        PMID: 27614538     DOI: 10.1016/j.jemermed.2016.06.031

Source DB:  PubMed          Journal:  J Emerg Med        ISSN: 0736-4679            Impact factor:   1.484


  3 in total

1.  Decision support for assessment of left ventricular diastolic function.

Authors:  Éva Tamás; Eva Nylander
Journal:  Physiol Rep       Date:  2018-08

2.  Emergency physician use of tissue Doppler bedside echocardiography in detecting diastolic dysfunction: an exploratory study.

Authors:  Marina Del Rios; Joseph Colla; Pavitra Kotini-Shah; Joan Briller; Ben Gerber; Heather Prendergast
Journal:  Crit Ultrasound J       Date:  2018-01-25

Review 3.  Point-of-care ultrasound in primary care: a systematic review of generalist performed point-of-care ultrasound in unselected populations.

Authors:  Bjarte Sorensen; Steinar Hunskaar
Journal:  Ultrasound J       Date:  2019-11-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.