Preanalytical errors in medical laboratories: a review of the available methodologies of data collection and analysis.

Jamie West1, Jennifer Atherton2, Seán J Costelloe3, Ghazaleh Pourmahram4, Adam Stretton4, Michael Cornes5.   

Abstract

Preanalytical errors have previously been shown to contribute a significant proportion of errors in laboratory processes and contribute to a number of patient safety risks. Accreditation against ISO 15189:2012 requires that laboratory Quality Management Systems consider the impact of preanalytical processes in areas such as the identification and control of non-conformances, continual improvement, internal audit and quality indicators. Previous studies have shown that there is a wide variation in the definition, repertoire and collection methods for preanalytical quality indicators. The International Federation of Clinical Chemistry Working Group on Laboratory Errors and Patient Safety has defined a number of quality indicators for the preanalytical stage, and the adoption of harmonized definitions will support interlaboratory comparisons and continual improvement. There are a variety of data collection methods, including audit, manual recording processes, incident reporting mechanisms and laboratory information systems. Quality management processes such as benchmarking, statistical process control, Pareto analysis and failure mode and effect analysis can be used to review data and should be incorporated into clinical governance mechanisms. In this paper, The Association for Clinical Biochemistry and Laboratory Medicine PreAnalytical Specialist Interest Group review the various data collection methods available. Our recommendation is the use of the laboratory information management systems as a recording mechanism for preanalytical errors as this provides the easiest and most standardized mechanism of data capture.

Entities:  

Keywords:  Preanalytical errors; laboratory errors; patient safety; quality indicators

Mesh:

Year:  2016        PMID: 27614351     DOI: 10.1177/0004563216669384

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  7 in total

1.  Preanalytical variables affecting the measurement of serum paraoxonase-1 activity in horses.

Authors:  Gabriele Rossi; Amy Richardson; Hali Jamaludin; Cristy Secombe
Journal:  J Vet Diagn Invest       Date:  2020-11-22       Impact factor: 1.279

2.  Internal quality assurance in diagnostic microbiology: A simple approach for insightful data.

Authors:  Valentin Scherz; Christian Durussel; Gilbert Greub
Journal:  PLoS One       Date:  2017-11-14       Impact factor: 3.240

3.  Novel Opportunities for Improving the Quality of Preanalytical Phase. A Glimpse to the Future?

Authors:  Giuseppe Lippi; Janne Cadamuro
Journal:  J Med Biochem       Date:  2017-10-28       Impact factor: 3.402

Review 4.  Vein Pattern Locating Technology for Cannulation: A Review of the Low-Cost Vein Finder Prototypes Utilizing near Infrared (NIR) Light to Improve Peripheral Subcutaneous Vein Selection for Phlebotomy.

Authors:  Cheng-Tang Pan; Mark D Francisco; Chung-Kun Yen; Shao-Yu Wang; Yow-Ling Shiue
Journal:  Sensors (Basel)       Date:  2019-08-16       Impact factor: 3.576

5.  Six Sigma performance of quality indicators in total testing process of point-of-care glucose measurement: A two-year review.

Authors:  Anne Vincent; Donnah Pocius; Yun Huang
Journal:  Pract Lab Med       Date:  2021-03-19

6.  Case report of spuriously low sodium and calcium in a 36-year-old male in primary care.

Authors:  Seán J Costelloe; Kelly McCarthy; Marguerite O'Connell; Mark Butler
Journal:  Biochem Med (Zagreb)       Date:  2020-04-15       Impact factor: 2.313

7.  Is it True Hypoparathyroidism? A Root Cause Analysis of Unusually Low Intact Parathyroid Hormone (iPTH) at a Clinical Laboratory.

Authors:  Sibtain Ahmed; Lena Jafri; Syed Muhammad Akhtar Shah; Nasreen Bano; Imran Siddiqui