Literature DB >> 27614069

A free software for the calculation of T2* values for iron overload assessment.

Juliano Lara Fernandes1, Luciana Andrea Barozi Fioravante1, Monica P Verissimo2, Sandra R Loggetto3.   

Abstract

Background Iron overload assessment with magnetic resonance imaging (MRI) using T2* has become a key diagnostic method in the management of many diseases. Quantitative analysis of the MRI images with a cost-effective tool has been a limitation to increased use of the method. Purpose To provide a free software solution for this purpose comparing the results with a commercial solution. Material and Methods The free tool was developed as a standalone program to be directly downloaded and ran in a common personal computer platform without the need of a dedicated workstation. Liver and cardiac T2* values were calculated using both tools and the values obtained compared between them in a group of 56 patients with suspected iron overload using Bland-Altman plots and concordance correlation coefficients (CCC). Results In the heart, the mean T2* differences between the two methods was 0.46 ms (95% confidence interval [CI], -0.037 -0.965) and in the liver 0.49 ms (95% CI, 0.257-0.722). The CCC for both the heart and the liver were significantly high (0.98 [95% CI, 0.966-0.988] with a Pearson ρ of 0.9811 and 0.991 [95% CI, 0.986-0.994] with a Pearson ρ of 0.996, respectively. No significant differences were observed when analyzing only patients with abnormal concentrations of iron in both organs compared to the whole cohort. Conclusion The proposed free software tool is accurate for calculation of T2* values of the liver and heart and might be a solution for centers that cannot use paid commercial solutions.

Entities:  

Keywords:  Magnetic resonance imaging (MRI); T2*; iron overload; software

Mesh:

Year:  2016        PMID: 27614069     DOI: 10.1177/0284185116666416

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  2 in total

1.  Use of rapid cardiac magnetic resonance imaging to guide chelation therapy in patients with transfusion-dependent thalassaemia in India: UMIMI study.

Authors:  Katia Menacho Medina; Amna Abdel-Gadir; Kartik Ganga; Vineeta Ojha; Surya Pratap; Redha Boubertakh; Louise McGrath; João B Augusto; Alexander Rikowski; Nabila Mughal; Virender Kumar Khanna; Tulika Seth; Sanjiv Sharma; Amita Mahajan; Rajiv K Bansal; Prabhar Srivastava; Harsh Mahajan; Vidhur Mahajan; Judith Walker; Tenzin Seldon; Emmanuel Ako; James C Moon; John Malcolm Walker
Journal:  Eur Heart J Qual Care Clin Outcomes       Date:  2022-05-05

2.  Cardiovascular magnetic resonance native T2 and T2* quantitative values for cardiomyopathies and heart transplantations: a systematic review and meta-analysis.

Authors:  G J H Snel; M van den Boomen; L M Hernandez; C T Nguyen; D E Sosnovik; B K Velthuis; R H J A Slart; R J H Borra; N H J Prakken
Journal:  J Cardiovasc Magn Reson       Date:  2020-05-11       Impact factor: 5.364

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.