Answers to if the Lead Aprons are Really Helpful in Nuclear Medicine from the Perspective of Spectroscopy.

X He1,2, R Zhao2, L Rong3, K Yao1, S Chen4, B Wei1.   

Abstract

Wearing lead X-ray-protective aprons is a routine in nuclear medicine department in parts of China. However, the staff are often perplexed by questions such as if it is imperative to wear aprons when injecting radioactive drugs, how much radiation dosage can be shielded and if the apron will produce secondary radiation instead? To answer these questions, a semiconductor detector was employed to record different gamma and X-ray spectra with and without the lead apron or lead sheet. Then, we could estimate the signal shielding ratio to different photons for the lead apron and compare with the hospitals measured data. In general, the two results coincided well. The spectral results showed that the detrimental secondary X-rays irradiation rises when the energy of gamma rays exceeds the K absorption edge of lead (88 keV). Moreover, the aprons are not so effective for gamma rays of 364 keV emitted from 131I and 511 keV emitted from the positron radioactive nuclides. This work is purely a physical measurement in the laboratory. To the best of our knowledge, this is the first quantitative study on the level of gamma rays protection offered by the medical lead aprons and the importance of the spectroscopic measurements is discussed in this paper.
© The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 27613748     DOI: 10.1093/rpd/ncw255

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  2 in total

1.  Perceptions on radioprotective garment usage and underlying reasons for non-adherence among medical radiation workers from public hospitals in a middle-income Asian setting: A qualitative exploration.

Authors:  Siti Farizwana Mohd Ridzwan; Nirmala Bhoo-Pathy; Marzuki Isahak; Lei Hum Wee
Journal:  Heliyon       Date:  2019-09-19

2.  Evaluation of Annual Staff Doses and Radiation Shielding Efficiencies of Thyroid Shield and Lead Apron during Preparation and Administration of 131I, 81Kr, and 99mTc-Labeled Radiopharmaceuticals.

Authors:  Nayereh Khalili; Seyed Salman Zakariaee; Elahe Jazayeri Gharebaghi; Yalda Salehi; Vahid Changizi
Journal:  J Med Signals Sens       Date:  2021-12-28
  2 in total