Literature DB >> 27612672

Noninvasive assessment of the intracranial pressure in non-traumatic intracranial hemorrhage.

Michael Vaiman1, Tal Sigal2, Itzhak Kimiagar3, Inessa Bekerman2.   

Abstract

The article describes the modified technique of measuring the diameters of the optic nerve sheath (ONSD) for assessment of the intracranial pressure (ICP) in patients with intracerebral or subarachnoid hemorrhage (SAH). The CT scans of 443 patients were analyzed retrospectively. The ONSDs were measured at 3mm behind the globe and at the point where the ophthalmic artery crosses the optic nerve. The ONSD/eyeball transverse diameter (ETD) ratio was calculated. The correlation analysis was performed with the Glasgow Coma Scale score, Hemispheric Stroke Scale score, Glasgow Outcome Score, and invasive ICP readings. ONSD was enlarged in 95% of patients with intracerebral hemorrhage or SAH. Pathological ONSDs were 6.6±0.8mm (cut-off value >5.5mm; p<0.05). ONSD/ETD ratio was 0.29±0.05 against normative 0.19±0.02 (p<0.01) with no correlation with initial Glasgow Coma Scale score or Hemispheric Stroke Scale score. There was an inverse correlation between ONSD/ETD ratio and Glasgow Outcome Score (r=-0.7) and direct correlation with invasive ICP readings. This study provides further evidence that in patients with intracranial hemorrhage and SAH, the presence of ONSD greater than a threshold of 5.5mm is significantly predictive of invasively measured elevated ICP. The prediction of raised ICP can be further refined by measuring ONSD at the point where the optic nerve and the ophthalmic artery cross, and by determining the ratio between the ONSD and ETD.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Adults; Computed tomography (CT) scan; Hemorrhagic stroke; Intracranial pressure; Non-traumatic intracerebral hemorrhage (ICH); Optic nerve sheath diameter

Mesh:

Year:  2016        PMID: 27612672     DOI: 10.1016/j.jocn.2016.06.008

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  7 in total

Review 1.  Management of Elevated Intracranial Pressure: a Review.

Authors:  Abhinav R Changa; Barry M Czeisler; Aaron S Lord
Journal:  Curr Neurol Neurosci Rep       Date:  2019-11-26       Impact factor: 5.081

2.  Ultrasonographic measurement of the optic nerve sheath diameter and its association with eyeball transverse diameter in 585 healthy volunteers.

Authors:  Dong Hwan Kim; Jin-Sun Jun; Ryul Kim
Journal:  Sci Rep       Date:  2017-11-21       Impact factor: 4.379

3.  Measurement of the Optic Nerve Sheath Diameter with Magnetic Resonance Imaging and Its Association with Eyeball Diameter in Healthy Adults.

Authors:  Dong Hwan Kim; Jin Sun Jun; Ryul Kim
Journal:  J Clin Neurol       Date:  2018-05-31       Impact factor: 3.077

4.  Diagnostic tool for initial evaluation of the intracranial pressure on computed tomography in pediatric patients with headache.

Authors:  Tetiana Bartsikhovsky; Miriam M Klar; Inessa Bekerman; Saida Nagieva; Sigal Tal
Journal:  PLoS One       Date:  2019-05-14       Impact factor: 3.240

5.  Is it the time to standardize the procedure of ultrasound guided optic nerve sheath diameter measurement?

Authors:  Summit D Bloria; Pallavi Bloria; Ankur Luthra
Journal:  Saudi J Anaesth       Date:  2019 Jul-Sep

6.  The clinical and prognostic values of optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in comatose patients with supratentorial lesions.

Authors:  Sha Zhu; Chao Cheng; Dianjiang Zhao; Yuanli Zhao; Xianzeng Liu; Jun Zhang
Journal:  BMC Neurol       Date:  2021-07-02       Impact factor: 2.474

7.  A noninvasive method for the estimation of increased intracranial pressure in patients with severe traumatic brain injury using optic nerve sheath diameter measured on computed tomography head.

Authors:  Gohar Majeed; Samir Kashyap; Rosalinda Menoni; Dan Miulli; Raed Sweiss
Journal:  Surg Neurol Int       Date:  2019-06-07
  7 in total