Literature DB >> 27612048

Robust low-dose dynamic cerebral perfusion CT image restoration via coupled dictionary learning scheme.

Xiumei Tian1,2, Dong Zeng1,2, Shanli Zhang3, Jing Huang1,2, Hua Zhang1,2, Ji He1,2, Lijun Lu1,2, Weiwen Xi1,2, Jianhua Ma1,2, Zhaoying Bian1,2.   

Abstract

Dynamic cerebral perfusion x-ray computed tomography (PCT) imaging has been advocated to quantitatively and qualitatively assess hemodynamic parameters in the diagnosis of acute stroke or chronic cerebrovascular diseases. However, the associated radiation dose is a significant concern to patients due to its dynamic scan protocol. To address this issue, in this paper we propose an image restoration method by utilizing coupled dictionary learning (CDL) scheme to yield clinically acceptable PCT images with low-dose data acquisition. Specifically, in the present CDL scheme, the 2D background information from the average of the baseline time frames of low-dose unenhanced CT images and the 3D enhancement information from normal-dose sequential cerebral PCT images are exploited to train the dictionary atoms respectively. After getting the two trained dictionaries, we couple them to represent the desired PCT images as spatio-temporal prior in objective function construction. Finally, the low-dose dynamic cerebral PCT images are restored by using a general DL image processing. To get a robust solution, the objective function is solved by using a modified dictionary learning based image restoration algorithm. The experimental results on clinical data show that the present method can yield more accurate kinetic enhanced details and diagnostic hemodynamic parameter maps than the state-of-the-art methods.

Entities:  

Keywords:  Low-dose; computed tomography; dictionary learning; dynamic cerebral perfusion; image restoration

Mesh:

Year:  2016        PMID: 27612048     DOI: 10.3233/XST-160593

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  2 in total

1.  [Sinogram restoration for low-dose cerebral perfusion CT images].

Authors:  Xiu-Mei Tian; Jing Huang; Jia-Hui Lin; Xin-Yu Zhang; Jian-Hua Ma; Zhao-Ying Bian
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2016-04-20

2.  Low-Dose Dynamic Cerebral Perfusion Computed Tomography Reconstruction via Kronecker-Basis-Representation Tensor Sparsity Regularization.

Authors:  Dong Zeng; Qi Xie; Wenfei Cao; Jiahui Lin; Hao Zhang; Shanli Zhang; Jing Huang; Zhaoying Bian; Deyu Meng; Zongben Xu; Zhengrong Liang; Wufan Chen; Jianhua Ma
Journal:  IEEE Trans Med Imaging       Date:  2017-09-04       Impact factor: 10.048

  2 in total