Literature DB >> 27610829

Simultaneous Determination of Oxygen and pH Inside Microfluidic Devices Using Core-Shell Nanosensors.

Josef Ehgartner1, Martin Strobl1, Juan M Bolivar2, Dominik Rabl1, Mario Rothbauer3, Peter Ertl3, Sergey M Borisov1, Torsten Mayr1.   

Abstract

A powerful online analysis setup for the simultaneous detection of oxygen and pH is presented. It features core-shell nanosensors, which enable contactless and inexpensive read-out using adapted oxygen meters via modified dual lifetime referencing in the frequency domain (phase shift measurements). Lipophilic indicator dyes were incorporated into core-shell structured poly(styrene-block-vinylpyrrolidone) nanoparticles (average diameter = 180 nm) yielding oxygen nanosensors and pH nanosensors by applying different preparation protocols. The oxygen indicator platinum(II) meso-tetra(4-fluorophenyl) tetrabenzoporphyrin (PtTPTBPF) was entrapped into the polystyrene core (oxygen nanosensors) and a pH sensitive BF2-chelated tetraarylazadipyrromethene dye (aza-BODIPY) was incorporated into the polyvinylpyrrolidone shell (pH nanosensors). The brightness of the pH nanoparticles was increased by more than 3 times using a light harvesting system. The nanosensors have several advantages such as being excitable with red light, emitting in the near-infrared spectral region, showing a high stability in aqueous media even at high particle concentrations, high ionic strength, or high protein concentrations and are spectrally compatible with the used read-out device. The resolution for oxygen of the setup is 0.5-2.0 hPa (approximately 0.02-0.08 mg/L of dissolved oxygen) at low oxygen concentrations (<50 hPa) and 4-8 hPa (approximately 0.16-0.32 mg/L of dissolved oxygen) at ambient air oxygen concentrations (approximately 200 hPa at 980 mbar air pressure) at room temperature. The pH resolution is 0.03-0.1 pH units within the dynamic range (apparent pKa 7.23 ± 1.0) of the nanosensors. The sensors were used for online monitoring of pH changes during the enzymatic transformation of Penicillin G to 6-aminopenicillanic acid catalyzed by Penicillin G acylase in miniaturized stirred batch reactors or continuous flow microreactors.

Entities:  

Year:  2016        PMID: 27610829     DOI: 10.1021/acs.analchem.6b02849

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  Novel epoxy-silica nanoparticles to develop non-enzymatic colorimetric probe for analytical immuno/bioassays.

Authors:  Chandra K Dixit; Snehasis Bhakta; John Macharia; Jared Furtado; Steven L Suib; James F Rusling
Journal:  Anal Chim Acta       Date:  2018-04-24       Impact factor: 6.558

2.  Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications.

Authors:  Andreas Steinegger; Otto S Wolfbeis; Sergey M Borisov
Journal:  Chem Rev       Date:  2020-11-04       Impact factor: 60.622

3.  In-Line Analysis of Organ-on-Chip Systems with Sensors: Integration, Fabrication, Challenges, and Potential.

Authors:  Stefanie Fuchs; Sofia Johansson; Anders Ø Tjell; Gabriel Werr; Torsten Mayr; Maria Tenje
Journal:  ACS Biomater Sci Eng       Date:  2021-06-16

4.  Characterization of four functional biocompatible pressure-sensitive adhesives for rapid prototyping of cell-based lab-on-a-chip and organ-on-a-chip systems.

Authors:  S R A Kratz; C Eilenberger; P Schuller; B Bachmann; S Spitz; P Ertl; M Rothbauer
Journal:  Sci Rep       Date:  2019-06-26       Impact factor: 4.379

Review 5.  Technology Advancements in Blood Coagulation Measurements for Point-of-Care Diagnostic Testing.

Authors:  Mohammad Mohammadi Aria; Ahmet Erten; Ozlem Yalcin
Journal:  Front Bioeng Biotechnol       Date:  2019-12-11

6.  Every Breath You Take: Non-invasive Real-Time Oxygen Biosensing in Two- and Three-Dimensional Microfluidic Cell Models.

Authors:  Helene Zirath; Mario Rothbauer; Sarah Spitz; Barbara Bachmann; Christian Jordan; Bernhard Müller; Josef Ehgartner; Eleni Priglinger; Severin Mühleder; Heinz Redl; Wolfgang Holnthoner; Michael Harasek; Torsten Mayr; Peter Ertl
Journal:  Front Physiol       Date:  2018-07-03       Impact factor: 4.566

7.  Downscaling screening cultures in a multifunctional bioreactor array-on-a-chip for speeding up optimization of yeast-based lactic acid bioproduction.

Authors:  Damiano Totaro; Mario Rothbauer; Matthias G Steiger; Torsten Mayr; Hsiang-Yu Wang; Yu-Sheng Lin; Michael Sauer; Martin Altvater; Peter Ertl; Diethard Mattanovich
Journal:  Biotechnol Bioeng       Date:  2020-04-06       Impact factor: 4.530

Review 8.  Microfluidic-Based Oxygen (O2) Sensors for On-Chip Monitoring of Cell, Tissue and Organ Metabolism.

Authors:  Mostafa Azimzadeh; Patricia Khashayar; Meitham Amereh; Nishat Tasnim; Mina Hoorfar; Mohsen Akbari
Journal:  Biosensors (Basel)       Date:  2021-12-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.