Literature DB >> 27604749

A method to approximate maximum local SAR in multichannel transmit MR systems without transmit phase information.

Stephan Orzada1, Mark E Ladd1,2, Andreas K Bitz1.   

Abstract

PURPOSE: To calculate local specific absorption rate (SAR) correctly, both the amplitude and phase of the signal in each transmit channel have to be known. In this work, we propose a method to derive a conservative upper bound for the local SAR, with a reasonable safety margin without knowledge of the transmit phases of the channels.
METHODS: The proposed method uses virtual observation points (VOPs). Correction factors are calculated for each set of VOPs that prevent underestimation of local SAR when the VOPs are applied with the correct amplitudes but fixed phases.
RESULTS: The proposed method proved to be superior to the worst-case calculation based on the maximum eigenvalue of the VOPs. The mean overestimation for six coil setups could be reduced, whereas no underestimation of the maximum local SAR occurred. In the best investigated case, the overestimation could be reduced from a factor of 3.3 to a factor of 1.7.
CONCLUSION: The upper bound for the local SAR calculated with the proposed method allows a fast estimation of the local SAR based on power measurements in the transmit channels and facilitates SAR monitoring in systems that do not have the capability to monitor transmit phases. Magn Reson Med 78:805-811, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Mesh:

Year:  2016        PMID: 27604749     DOI: 10.1002/mrm.26398

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Real-time assessment of potential peak local specific absorption rate value without phase monitoring: Trigonometric maximization method for worst-case local specific absorption rate determination.

Authors:  Ettore Flavio Meliadò; Alessandro Sbrizzi; Cornelis A T van den Berg; Peter R Luijten; Alexander J E Raaijmakers
Journal:  Magn Reson Med       Date:  2020-12-22       Impact factor: 4.668

Review 2.  Progress in Imaging the Human Torso at the Ultrahigh Fields of 7 and 10.5 T.

Authors:  Kamil Uğurbil; Pierre-Francois Van de Moortele; Andrea Grant; Edward J Auerbach; Arcan Ertürk; Russell Lagore; Jutta M Ellermann; Xiaoxuan He; Gregor Adriany; Gregory J Metzger
Journal:  Magn Reson Imaging Clin N Am       Date:  2021-02       Impact factor: 2.266

3.  An 8-channel Tx/Rx dipole array combined with 16 Rx loops for high-resolution functional cardiac imaging at 7 T.

Authors:  Bart R Steensma; Ingmar J Voogt; Tim Leiner; Peter R Luijten; Jesse Habets; Dennis W J Klomp; Cornelis A T van den Berg; Alexander J E Raaijmakers
Journal:  MAGMA       Date:  2017-11-24       Impact factor: 2.310

Review 4.  Evolution of UHF Body Imaging in the Human Torso at 7T: Technology, Applications, and Future Directions.

Authors:  M Arcan Erturk; Xiufeng Li; Pierre-Fancois Van de Moortele; Kamil Ugurbil; Gregory J Metzger
Journal:  Top Magn Reson Imaging       Date:  2019-06

5.  A 32-channel parallel transmit system add-on for 7T MRI.

Authors:  Stephan Orzada; Klaus Solbach; Marcel Gratz; Sascha Brunheim; Thomas M Fiedler; Sören Johst; Andreas K Bitz; Samaneh Shooshtary; Ashraf Abuelhaija; Maximilian N Voelker; Stefan H G Rietsch; Oliver Kraff; Stefan Maderwald; Martina Flöser; Mark Oehmigen; Harald H Quick; Mark E Ladd
Journal:  PLoS One       Date:  2019-09-12       Impact factor: 3.240

6.  Conditional safety margins for less conservative peak local SAR assessment: A probabilistic approach.

Authors:  Ettore Flavio Meliadò; Alessandro Sbrizzi; Cornelis A T van den Berg; Bart R Steensma; Peter R Luijten; Alexander J E Raaijmakers
Journal:  Magn Reson Med       Date:  2020-06-03       Impact factor: 4.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.