Literature DB >> 27601249

Fully automatic input function determination program for simple noninvasive (123)I-IMP microsphere cerebral blood flow quantification method.

Kosuke Yamashita1, Yoshikazu Uchiyama2, Asato Ofuji3, Hiroaki Mimura4, Shintaro Okumiya3, Akihiro Takaki5, Teruki Sone4, Shigeki Ito6.   

Abstract

We recently developed a simple noninvasive (123)I-IMP microsphere (SIMS) method using chest dynamic planar images and brain single photon emission computed tomography. The SIMS method is an automatic analysis method, except for the process of setting the region of interest (ROI) of the input function. If a fully automatic ROI setting algorithm can be developed to determine the input function for the SIMS method, repeatability and reproducibility of the analysis of regional cerebral blood flow (rCBF) of the SIMS method can be guaranteed. The purpose of this study is to develop a fully automatic input function determination program for the SIMS method and to confirm the clinical usefulness of this program. The automatic input function determination program consists of two ROI setting programs for the PA and lung regions, and it is developed using the image phase analysis of a chest RI angiogram. To confirm the clinical usefulness of this program, the rCBF in 34 patients measured using the automatic method were compared with the values obtained through the manual setting method. Input functions by the automatic and manual methods were approximately equal. A good correlation was observed between the rCBF values obtained by the automatic method and those obtained by the manual setting method (r=0.96, p<0.01). Further, the total time taken for the automatic SIMS analysis is 1-2min as compared to 20-30min for the current analysis, and therefore, this technique contributes to the improvement of the throughput of nuclear medical examinations.
Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  (123)I-IMP SPECT; Fully automatic program; Noninvasive quantitative measurements; rCBF

Mesh:

Substances:

Year:  2016        PMID: 27601249     DOI: 10.1016/j.ejmp.2016.08.021

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  3 in total

1.  Uptake Index of 123I-metaiodobenzylguanidine Myocardial Scintigraphy for Diagnosing Lewy Body Disease.

Authors:  Yoshito Kamiya; Satoru Ota; Shintaro Okumiya; Kosuke Yamashita; Akihiro Takaki; Shigeki Ito
Journal:  Asia Ocean J Nucl Med Biol       Date:  2017

2.  A Simple Non-invasive I-123-IMP Autoradiography Method Developed by Modifying the Simple Non-invasive I-123-IMP Microsphere Method.

Authors:  Asato Ofuji; Rieko Nagaoka; Kosuke Yamashita; Akihiro Takaki; Shigeki Ito
Journal:  Asia Ocean J Nucl Med Biol       Date:  2018

3.  Development of an 123I-metaiodobenzylguanidine Myocardial Three-Dimensional Quantification Method for the Diagnosis of Lewy Body Disease.

Authors:  Yoshito Kamiya; Satoru Ota; Yuta Tanaka; Kosuke Yamashita; Akihiro Takaki; Shigeki Ito
Journal:  Asia Ocean J Nucl Med Biol       Date:  2018
  3 in total