Literature DB >> 27598854

Multimodal technique to eliminate humidity interference for specific detection of ethanol.

Ahmed Hasnain Jalal1, Yogeswaran Umasankar2, Pablo J Gonzalez1, Alejandro Alfonso1, Shekhar Bhansali3.   

Abstract

Multimodal electrochemical technique incorporating both open circuit potential (OCP) and amperometric techniques have been conceptualized and implemented to improve the detection of specific analyte in systems where more than one analyte is present. This approach has been demonstrated through the detection of ethanol while eliminating the contribution of water in a micro fuel cell sensor system. The sensor was interfaced with LMP91000 potentiostat, controlled through MSP430F5529LP microcontroller to implement an auto-calibration algorithm tailored to improve the detection of alcohol. The sensor was designed and fabricated as a three electrode system with Nafion as a proton exchange membrane (PEM). The electrochemical signal of the interfering phase (water) was eliminated by implementing the multimodal electrochemical detection technique. The results were validated by comparing sensor and potentiostat performances with a commercial sensor and potentiostat respectively. The results suggest that such a sensing system can detect ethanol at concentrations as low as 5ppm. The structure and properties such as low detection limit, selectivity and miniaturized size enables potential application of this device in wearable transdermal alcohol measurements. Copyright Â
© 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Continuous monitoring; Ethanol; Fuel cell; Nafion; Potentiostat; Wearable

Mesh:

Substances:

Year:  2016        PMID: 27598854     DOI: 10.1016/j.bios.2016.08.106

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Thermochemical Humidity Detection in Harsh or Non-Steady Environments.

Authors:  Devon Bridgeman; Francis Tsow; Xiaojun Xian; Qinan Chang; Yongming Liu; Erica Forzani
Journal:  Sensors (Basel)       Date:  2017-05-24       Impact factor: 3.576

2.  A COTS-Based Portable System to Conduct Accurate Substance Concentration Measurements.

Authors:  Juan Aznar-Poveda; Jose Antonio Lopez-Pastor; Antonio-Javier Garcia-Sanchez; Joan Garcia-Haro; Toribio Fernández Otero
Journal:  Sensors (Basel)       Date:  2018-02-10       Impact factor: 3.576

3.  KickStat: A Coin-Sized Potentiostat for High-Resolution Electrochemical Analysis.

Authors:  Orlando S Hoilett; Jenna F Walker; Bethany M Balash; Nicholas J Jaras; Sriram Boppana; Jacqueline C Linnes
Journal:  Sensors (Basel)       Date:  2020-04-23       Impact factor: 3.576

4.  Influence of the aromatic surface on the capacity of adsorption of VOCs by magnetite supported organic-inorganic hybrids.

Authors:  María de Las Nieves Piña; María Susana Gutiérrez; Mario Panagos; Paulino Duel; Alberto León; Jeroni Morey; David Quiñonero; Antonio Frontera
Journal:  RSC Adv       Date:  2019-08-05       Impact factor: 4.036

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.