Erik A Wikstrom1, Gary Allen1. 1. a Department of Exercise & Sport Science , University of North Carolina at Chapel Hill , Chapel Hill , NC , USA.
Abstract
PURPOSE: A 4-2-1 stepping algorithm reliably captures light touch thresholds but has not been used to assess two-point discrimination (TPD) thresholds. Therefore, the purpose of this investigation was to determine the intra- and inter-rater reliability of a 4-2-1 stepping algorithm at determining TPD thresholds. MATERIALS AND METHODS: Fifteen healthy, physically active young adults were assessed twice over a 1-week period using digital calipers and a 4-2-1 stepping algorithm. TPD thresholds were assessed by an expert and a novice examiner at each time point. Reliability was assessed on the plantar surface of the foot at the head of the first and base of the fifth metatarsal. RESULTS: Three intra-rater intraclass correlation coefficient (ICC) values exceeded 0.75 and were interpreted as good. The inter-rater reliability was good with ICC values ranging from 0.76 to 0.93 at both sites during both test sessions. CONCLUSIONS: The 4-2-1 stepping algorithm demonstrates good intra- and inter-tester reliability at determining TPD thresholds on the plantar surface of the foot at the head of the first and base of the fifth metatarsal in young healthy adults.
PURPOSE: A 4-2-1 stepping algorithm reliably captures light touch thresholds but has not been used to assess two-point discrimination (TPD) thresholds. Therefore, the purpose of this investigation was to determine the intra- and inter-rater reliability of a 4-2-1 stepping algorithm at determining TPD thresholds. MATERIALS AND METHODS: Fifteen healthy, physically active young adults were assessed twice over a 1-week period using digital calipers and a 4-2-1 stepping algorithm. TPD thresholds were assessed by an expert and a novice examiner at each time point. Reliability was assessed on the plantar surface of the foot at the head of the first and base of the fifth metatarsal. RESULTS: Three intra-rater intraclass correlation coefficient (ICC) values exceeded 0.75 and were interpreted as good. The inter-rater reliability was good with ICC values ranging from 0.76 to 0.93 at both sites during both test sessions. CONCLUSIONS: The 4-2-1 stepping algorithm demonstrates good intra- and inter-tester reliability at determining TPD thresholds on the plantar surface of the foot at the head of the first and base of the fifth metatarsal in young healthy adults.
Keywords:
Somatosensory function; plantar surface; young adults
Authors: Melina N Haik; Francisco Alburquerque-Sendín; Ricardo A S Fernandes; Danilo H Kamonseki; Lucas A Almeida; Richard E Liebano; Paula R Camargo Journal: Diagnostics (Basel) Date: 2020-11-10