Literature DB >> 27595169

Molecularly imprinted polymer based micromechanical cantilever sensor system for the selective determination of ciprofloxacin.

Meltem Okan1, Esma Sari2, Memed Duman3.   

Abstract

The main objective of this study is to develop molecularly imprinted polymer (MIP) based micromechanical cantilever sensor system that has high specificity, fast response time and is easily applicable by user for the detection of ciprofloxacin (CPX) molecule in water resources. Highly specific CPX imprinted nanoparticles were synthesized by miniemulsion polymerization technique. The average size of the synthesized nanoparticles was measured about 160nm with high monodispersivity. Covalent and monolayer binding of the MIP nanoparticles on cantilevers was provided by EDC/NHS activation. Validation of the developed cantilever nanosensor was performed in air with dip-and-dry technique by employing the dynamic sensing mode. According to the results obtained, micromechanical cantilever sensor system worked linearly for the concentration range of 1.5-150.9μM. This concentration range resulted with 18.4-48.9pg mass load on the MIP modified cantilever. The sensitivity of the developed sensor was calculated as 2.6Hz/pg. To control the specificity of MIPs, a different antibiotic enrofloxacin (ENF), with a similar physical and chemical structure with CPX, was used, which showed 7 folds low binding affinity. The developed highly specific microcantilever sensor has a response time of approximately 2min and is reusable up to 4 times. The results indicate that the MIP based AFM nanosensor has high sensitivity for the CPX molecule. This combination of MIP nanoparticles with micromechanical sensors is one of the pioneer studies in the mass sensing applications. This fast, low cost and highly sensitive CPX specific MIP nanoparticle based nanosensor developed in this research have the potential to pave the way for further studies.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ciprofloxacin; Microcantilever; Micromechanical biosensor

Mesh:

Substances:

Year:  2016        PMID: 27595169     DOI: 10.1016/j.bios.2016.08.047

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  8 in total

1.  Fluorometric determination of ciprofloxacin using molecularly imprinted polymer and polystyrene microparticles doped with europium(III)(DBM)3phen.

Authors:  Zhuanying Li; Zhimeng Cui; Yiwei Tang; Xiuying Liu; Xuemei Zhang; Bingxiang Liu; Xianghong Wang; Mohamed Shehata Draz; Xue Gao
Journal:  Mikrochim Acta       Date:  2019-05-07       Impact factor: 5.833

2.  Simple, fast and environmentally friendly method to determine ciprofloxacin in wastewater samples based on an impedimetric immunosensor.

Authors:  Rafaela Silva Lamarca; Ricardo Adriano Dorledo de Faria; Maria Valnice Boldrin Zanoni; Marcelo Nalin; Paulo Clairmont Feitosa de Lima Gomes; Younès Messaddeq
Journal:  RSC Adv       Date:  2020-01-08       Impact factor: 4.036

Review 3.  Imprinted Oxide and MIP/Oxide Hybrid Nanomaterials for Chemical Sensors .

Authors:  Adeel Afzal; Franz L Dickert
Journal:  Nanomaterials (Basel)       Date:  2018-04-20       Impact factor: 5.076

4.  Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications.

Authors:  Yugang Chen; Yong-Hwa Park
Journal:  Sensors (Basel)       Date:  2019-03-05       Impact factor: 3.576

Review 5.  Functionalized monolithic columns: Recent advancements and their applications for high-efficiency separation and enrichment in food and medicine.

Authors:  Helong Si; Quan Wang; Yuanyuan Guo; Yuxin Zhao; Hongya Li; Shuna Li; Shuxiang Wang; Baocheng Zhu
Journal:  Front Chem       Date:  2022-08-05       Impact factor: 5.545

6.  Molecularly imprinted polymer amalgamation on narrow-gapped Archimedean-spiral interdigitated electrodes: resistance to electrolyte fouling in acidic medium.

Authors:  Hemavathi Krishnan; Subash C B Gopinath; M K Md Arshad; Hanna IIyani Zulhaimi; Santheraleka Ramanathan
Journal:  Mikrochim Acta       Date:  2021-03-31       Impact factor: 5.833

Review 7.  How Reliable Is the Electrochemical Readout of MIP Sensors?

Authors:  Aysu Yarman; Frieder W Scheller
Journal:  Sensors (Basel)       Date:  2020-05-08       Impact factor: 3.576

Review 8.  Biosensors Based on Mechanical and Electrical Detection Techniques.

Authors:  Thomas Chalklen; Qingshen Jing; Sohini Kar-Narayan
Journal:  Sensors (Basel)       Date:  2020-09-30       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.