Literature DB >> 27592320

Treatment of Ni-EDTA containing wastewater by electrocoagulation using iron scraps packed-bed anode.

Xiaokun Ye1, Junya Zhang2, Yan Zhang2, Yuancai Lv2, Rongni Dou2, Shulong Wen2, Lianghao Li2, Yuancai Chen3, YongYou Hu2.   

Abstract

The unique electrocoagulator proposed in this study is highly efficient at removing Ni-EDTA, providing a potential remediation option for wastewater containing lower concentrations of Ni-EDTA (Ni ≤ 10 mg L-1). In the electrocoagulation (EC) system, cylindrical graphite was used as a cathode, and a packed-bed formed from iron scraps was used as an anode. The results showed that the removal of Ni-EDTA increased with the application of current and favoured acidic conditions. We also found that the iron scrap packed-bed anode was superior in its treatment ability and specific energy consumption (SECS) compared with the iron rod anode. In addition, the packed density and temperature had a large influence on the energy consumption (ECS). Over 94.3% of Ni and 95.8% of TOC were removed when conducting the EC treatment at an applied current of 0.5 A, initial pH of 3, air-purged rate 0.2 L min-1, anode packed density of 400 kg m-3 temperature of 313 K and time of 30 min. SEM analysis of the iron scraps indicated that the specific area of the anode increased after the EC. The XRD analysis of flocs produced during EC revealed that hematite (α-Fe2O3) and magnetite (Fe3O4) were the main by-products under aerobic and anoxic conditions, respectively. A kinetic study demonstrated that the removal of Ni-EDTA followed a first-order model with the current parameters. Moreover, the removal efficiency of real wastewater was essentially consistent with that of synthetic wastewater.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aeration; Initial pH; Iron scrap anode; Packed density; Specific energy consumption

Mesh:

Substances:

Year:  2016        PMID: 27592320     DOI: 10.1016/j.chemosphere.2016.08.043

Source DB:  PubMed          Journal:  Chemosphere        ISSN: 0045-6535            Impact factor:   7.086


  3 in total

1.  Co-N-doped MoO2 modified carbon felt cathode for removal of EDTA-Ni in electro-Fenton process.

Authors:  Junya Zhang; Weijia Zhou; Linjing Yang; Yuancai Chen; Yongyou Hu
Journal:  Environ Sci Pollut Res Int       Date:  2018-05-31       Impact factor: 4.223

2.  Effect of calcination temperature on the properties of Ti/SnO2-Sb anode and its performance in Ni-EDTA electrochemical degradation.

Authors:  Xin Lei; Lianghao Li; Yuancai Chen; Yongyou Hu
Journal:  Environ Sci Pollut Res Int       Date:  2018-02-13       Impact factor: 4.223

3.  Decomplexation of Cu(II)/Ni(II)-EDTA by ozone-oxidation process.

Authors:  Suyun Xu; Ning Yan; Minghao Cui; Hongbo Liu
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-07       Impact factor: 4.223

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.