Rotational Atherectomy of Three Overlapping Stent Layers.

Tiberio M Frisoli1, Harold Friedman, William W O'Neill.   

Abstract

A patient was referred to us for Canadian Cardiovascular Society class III refractory angina. He was found to have in-stent restenosis within three layers of underexpanded stents implanted in 2004, 2011, and 2014. Rotational atherectomy safely yielded stent strut ablation (reduced to one layer), lesion expansion, and very good angiographic and physiologic results.

Entities:  

Mesh:

Year:  2016        PMID: 27591692

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  3 in total

1.  In-Stent Restenosis due to Stent Recoil After Third-Generation Drug-Eluting Stent Implantation.

Authors:  Yuta Kato; Atsushi Iwata; Masayuki Nakamura; Shin-Ichiro Miura; Keijiro Saku
Journal:  J Clin Med Res       Date:  2017-04-26

2.  Successful double-layer metal stents rotational ablation under 2-dimensional and 3-dimensional optical coherence tomography guidance: a case report.

Authors:  Tong Yaliang; Liu Guohui; Zhang Cheng; Du Beibei; Zhao Yanan; He Yuquan; Yang Ping
Journal:  BMC Cardiovasc Disord       Date:  2021-04-13       Impact factor: 2.298

3.  Long-term outcomes of rotational atherectomy of underexpanded stents. A single center experience.

Authors:  Marco Hernández-Enríquez; Francisco Campelo-Parada; Thibault Lhermusier; Frédéric Bouisset; Jérôme Roncalli; Meyer Elbaz; Didier Carrié; Nicolas Boudou
Journal:  J Interv Cardiol       Date:  2018-01-25       Impact factor: 2.279