Literature DB >> 27591663

Ultrasound assisted-deep eutectic solvent based on emulsification liquid phase microextraction combined with microsample injection flame atomic absorption spectrometry for valence speciation of chromium(III/VI) in environmental samples.

Erkan Yilmaz1, Mustafa Soylak2.   

Abstract

A new type of deep eutectic solvents (DESs) have been prepared and used as extraction solvents for ultrasound assisted-deep eutectic solvent based emulsification liquid phase microextraction method (UA-DES-ELPME) for the determination and speciation of total chromium, chromium(III) and chromium(VI). The chromium concentration in DES rich phase (extraction phase) was determined by using microsample injection flame atomic absorption spectrometer (FAAS). The detection limit (LOD), the quantification limit (LOQ), preconcentration factor and relative standard deviation were found as 5.5µgL(-1), 18.2µgL(-1), 20 and 6%, respectively. The accuracy of the developed method was evaluated by the analysis of water the certified reference materials (TMDA-53.3 Fortified environmental water and TMDA-54.4 Fortified Lake Water) and addition-recovery tests for water samples.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chromium; Deep eutectic solvent; Emulsification; Green chemistry; Liquid phase microextraction; Speciation

Year:  2016        PMID: 27591663     DOI: 10.1016/j.talanta.2016.08.001

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  7 in total

1.  Polyethylenimine-stabilized silver nanoclusters act as an oxidoreductase mimic for colorimetric determination of chromium(VI).

Authors:  Qiangsheng Xue; Xin Li; Yinxian Peng; Peng Liu; Hongbing Peng; Xiangheng Niu
Journal:  Mikrochim Acta       Date:  2020-04-08       Impact factor: 5.833

2.  Polystyrene-divinyl benzene microspheres with amino methyl phosphonic acid functional hairy brushes for the sorption and speciation of chromium prior to inductively coupled plasma mass spectrometric determination.

Authors:  Aslı Erdem Yayayürük; Onur Yayayürük; Ece Tukenmez; Bunyamin Karagoz
Journal:  Mikrochim Acta       Date:  2019-07-24       Impact factor: 5.833

3.  Carbon dots derived from Poria cocos polysaccharide as an effective "on-off" fluorescence sensor for chromium (VI) detection.

Authors:  Qianqian Huang; Qianqian Bao; Chengyuan Wu; Mengru Hu; Yunna Chen; Lei Wang; Weidong Chen
Journal:  J Pharm Anal       Date:  2021-05-01

4.  Preparation of polymethacrylate monolith modified with cysteine for the determination of Cr(iii) ions.

Authors:  Dan Liu; Junli Pan; Jianghong Tang; Ning Lian
Journal:  RSC Adv       Date:  2018-07-10       Impact factor: 4.036

5.  Optimization of choline chloride-glycerol based natural deep eutectic solvent for extraction bioactive substances from Cinnamomum burmannii barks and Caesalpinia sappan heartwoods.

Authors:  Aditya Sindu Sakti; Fadlina Chany Saputri; Abdul Mun'im
Journal:  Heliyon       Date:  2019-12-09

Review 6.  Microextraction Techniques with Deep Eutectic Solvents.

Authors:  Orfeas-Evangelos Plastiras; Eirini Andreasidou; Victoria Samanidou
Journal:  Molecules       Date:  2020-12-19       Impact factor: 4.411

7.  Deep Eutectic Solvent Micro-Functionalized Graphene Assisted Dispersive Micro Solid-Phase Extraction of Pyrethroid Insecticides in Natural Products.

Authors:  Xiaoyu Song; Rui Zhang; Tian Xie; Shuling Wang; Jun Cao
Journal:  Front Chem       Date:  2019-08-23       Impact factor: 5.221

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.