Simultaneous determination of iron and nickel in fluoropolymers by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry.

Bruno M Soares1, Rafael F Santos2, Rodrigo C Bolzan2, Edson I Muller2, Ednei G Primel1, Fabio A Duarte3.   

Abstract

This paper reports the development of a method of simultaneous determination of iron and nickel in fluoropolymers by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) with direct solid sampling. In order to carry out simultaneous measurements, both the main resonance line of nickel (232.003nm) and the adjacent secondary line of iron (232.036nm) were monitored in the same spectral window. The proposed method was optimized with a perfluoroalkoxy (PFA) sample and was applied to the determination of iron and nickel in fluorinated ethylene propylene (FEP) and modified polytetrafluoroethylene (PTFE-TFM) samples. Pyrolysis and atomization temperatures, as well as the use of Pd and H2 (during pyrolysis) as chemical modifiers, were carefully investigated. Compromise temperatures for pyrolysis and atomization of both analytes were achieved at 800 and 2300°C, respectively, using only 0.5Lmin(-1) H2 as chemical modifier during pyrolysis. Calibration curves were performed with aqueous standards by using a single solution which contained both analytes. Limits of detection were 221 and 9.6ngg(-1) for iron and nickel, respectively. Analyte concentrations in all samples ranged from 3.53 to 12.4µgg(-1) for iron and from 37 to 78ngg(-1) for nickel, with relative standard deviation less than 19%. Accuracy was evaluated by comparing these results with those obtained by inductively coupled plasma mass spectrometry after sample digestion by microwave-induced combustion and no significant statistical difference was observed.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fluoropolymer; HR-CS GF AAS; Iron; Nickel; Simultaneous determination; Solid sampling

Year:  2016        PMID: 27591638     DOI: 10.1016/j.talanta.2016.07.040

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Dual determination of nitrite and iron by a single greener sequential injection spectrophotometric system employing a simple single aqueous extract from Areca catechu Linn. serving as a natural reagent.

Authors:  Kraingkrai Ponhong; Watsaka Siriangkhawut; Chang Young Lee; Norio Teshima; Kate Grudpan; Sam-Ang Supharoek
Journal:  RSC Adv       Date:  2022-07-11       Impact factor: 4.036

2.  Microwave-Assisted Rapid Synthesis of Luminescent Tryptophan-Stabilized Silver Nanoclusters for Ultra-Sensitive Detection of Fe(III), and Their Application in a Test Strip.

Authors:  Sayed M Saleh; Wael A El-Sayed; May A El-Manawaty; Malek Gassoumi; Reham Ali
Journal:  Biosensors (Basel)       Date:  2022-06-16
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.