Literature DB >> 27591527

Concentrations of monoaromatic hydrocarbons in the air of the underground car park and individual garages attached to residential buildings.

Mariusz Marć1, Monika Śmiełowska2, Bożena Zabiegała2.   

Abstract

The paper describes the characteristics of a two-level underground car park and three individual garages attached to residential buildings, differing by the resident utilization habits, located in North Poland (Tri-City agglomeration area). The strategy of collecting the analyte samples from air in mentioned enclosed areas, concerning the determination of benzene, toluene, ethylbenzene, o-xylene and p,m-xylenes (BTEX) concentrations was performed using passive sampling technique - Radiello® diffusive passive samplers with graphitised charcoal cartridge as a sorption medium. The stage of liberation and final determination of collected analytes was conducted with the use of thermal desorption-gas chromatography-flame ionisation detector (TD-GC-FID) system. As a result of the performed measurements in two-level underground car park, it was observed that the time-weighted average concentrations of BTEX in air were as follows: Level-1 - benzene - 5.2±1.1μg/m3, toluene - 12.3±2.4μg/m3, ethylbenzene 2.85±0.80μg/m3, o-xylene - 4.6±1.4μg/m3, p, m-xylenes - 8.8±2,4μg/m3; Level-2 - benzene - 5.2±1.1μg/m3, toluene - 12.9±3.6μg/m3, ethylbenzene - 2.73±0.79μg/m3, o-xylene - 4.2±1.1μg/m3, p, m-xylenes - 8.5±2.3μg/m3. As for residential garages, the time-weighted average concentrations of BTEX in air were in the following ranges: from 5.9 to 53μg/m3 (benzene), from 7.1 to 195μg/m3 (toluene), from 3.0 to 39μg/m3 (ethylbenzene), from 5.6 to 44μg/m3 (o-xylene) and from 6.3 to 99μg/m3 (p,m-xylenes). Also, BTEX concentration ratios such as: tol/benz ratio and (m, p)-xyl/et.benz coefficient, were calculated based on the obtained results to assess the "freshness" of air mass and the influence exerted by vehicle movement on the concentration of BTEX in air in studied enclosed areas. Copyright Â
© 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  BTEX; Passive sampling; Residential garages; Underground car park; Vehicle emissions

Mesh:

Substances:

Year:  2016        PMID: 27591527     DOI: 10.1016/j.scitotenv.2016.08.173

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  1 in total

Review 1.  Indoor air quality of everyday use spaces dedicated to specific purposes-a review.

Authors:  Mariusz Marć; Monika Śmiełowska; Jacek Namieśnik; Bożena Zabiegała
Journal:  Environ Sci Pollut Res Int       Date:  2017-11-30       Impact factor: 4.223

  1 in total