Literature DB >> 27590542

Controlled deposition of functionalized silica coated zinc oxide nano-assemblies at the air/water interface for blood cancer detection.

Chandra Mouli Pandey1, Srishti Dewan2, Seema Chawla3, Birendra Kumar Yadav4, Gajjala Sumana5, Bansi Dhar Malhotra6.   

Abstract

We report results of the studies relating to controlled deposition of the amino-functionalized silica-coated zinc oxide (Am-Si@ZnO) nano-assemblies onto an indium tin oxide (ITO) coated glass substrate using Langmuir-Blodgett (LB) technique. The monolayers have been deposited by transferring the spread solution of Am-Si@ZnO stearic acid prepared in chloroform at the air-water interface, at optimized pressure (16 mN/m), concentration (10 mg/ml) and temperature (23 °C). The high-resolution transmission electron microscopic studies of the Am-Si@ZnO nanocomposite reveal that the nanoparticles have a microscopic structure comprising of hexagonal assemblies of ZnO with typical dimensions of 30 nm. The surface morphology of the LB multilayer observed by scanning electron microscopy shows uniform surface of the Am-Si@ZnO film in the nanometer range (<80 nm). These electrodes have been utilized for chronic myelogenous leukemia (CML) detection by covalently immobilizing the amino-terminated oligonucleotide probe sequence via glutaraldehyde as a crosslinker. The response studies of these fabricated electrodes carried out using electrochemical impedance spectroscopy show that this Am-Si@ZnO LB film based nucleic acid sensor exhibits a linear response to complementary DNA (10(-6)-10(-16) M) with a detection limit of 1 × 10(-16) M. This fabricated platform is validated with clinical samples of CML positive patients and the results demonstrate its immense potential for clinical diagnosis.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cancer; Chronic myelogenous leukemia; Langmuir-blodgett monolayer; Nucleic acid biosensor; Zinc oxide

Mesh:

Substances:

Year:  2016        PMID: 27590542     DOI: 10.1016/j.aca.2016.07.024

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  1 in total

1.  An impedimetric biosensor based on electrophoretically assembled ZnO nanorods and carboxylated graphene nanoflakes on an indium tin oxide electrode for detection of the DNA of Escherichia coli O157:H7.

Authors:  Nandita Jaiswal; Chandra Mouli Pandey; Shipra Solanki; Ida Tiwari; Bansi Dhar Malhotra
Journal:  Mikrochim Acta       Date:  2019-12-03       Impact factor: 5.833

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.