Evaluation of RayStation robust optimisation for superficial target coverage with setup variation in breast IMRT.

Mikel Byrne1, Yunfei Hu2, Ben Archibald-Heeren2.   

Abstract

When planning breast IMRT, the distance of the CTV from the patient external surface is often less than the PTV margin required, presenting difficulties for ensuring CTV coverage. Several techniques have been proposed to ensure coverage in this scenario, one of which is robust optimisation; a technique that simultaneously optimises a plan in multiple geometries representing the worst case setup error expected. A range of plans were created utilising opposed tangential beams and these differing planning techniques, and were delivered and computed at 5 and 10 mm offsets perpendicular to the beam axes. The accuracy of dose computation was verified with a scintillator and film, and the surface dose coverage was evaluated for each of the plans in the offset positions. When 10 mm robust optimisation was used the CTV minimum, maximum and mean dose at the 5 and 10 mm offset locations were all within 3 % of those at the no offset setup. Robust optimisation was found to be comparable to other established planning methods for ensuring coverage of the breast CTV with setup variations.

Entities:  

Keywords:  Breast IMRT; Robust optimisation; Setup variation; Superficial coverage; Surface dose; Virtual bolus

Mesh:

Year:  2016        PMID: 27581727     DOI: 10.1007/s13246-016-0466-6

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  12 in total

1.  Dosimetric Planning Comparison for Left-Sided Breast Cancer Radiotherapy: The Clinical Feasibility of Four-Dimensional-Computed Tomography-Based Treatment Planning Optimization.

Authors:  Oi-Wai Chau; Hatim Fakir; Michael Lock; Robert Dinniwell; Francisco Perera; Abigail Erickson; Stewart Gaede
Journal:  Cureus       Date:  2022-05-06

2.  Characterization of robust optimization for VMAT plan for liver cancer.

Authors:  Hideharu Miura; Shuichi Ozawa; Hayate Kusaba; Yoshiko Doi; Masahiko Kenjo; Kiyoshi Yamada; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-15

3.  Static beam tomotherapy as an optimisation method in whole-breast radiation therapy (WBRT).

Authors:  Matthew Squires; Yunfei Hu; Mikel Byrne; Ben Archibald-Heeren; Sonja Cheers; Bruno Bosco; Amy Teh; Andrew Fong
Journal:  J Med Radiat Sci       Date:  2017-06-04

4.  Robust optimization of VMAT for lung cancer: Dosimetric implications of motion compensation techniques.

Authors:  Ben R Archibald-Heeren; Mikel V Byrne; Yunfei Hu; Meng Cai; Yang Wang
Journal:  J Appl Clin Med Phys       Date:  2017-08-08       Impact factor: 2.102

5.  Efficacy of robust optimization plan with partial-arc VMAT for photon volumetric-modulated arc therapy: A phantom study.

Authors:  Hideharu Miura; Shuichi Ozawa; Yasushi Nagata
Journal:  J Appl Clin Med Phys       Date:  2017-07-10       Impact factor: 2.102

6.  Comparison of semiautomated tangential VMAT with 3DCRT for breast or chest wall and regional nodes.

Authors:  Mikel Byrne; Ben Archibald-Heeren; Yunfei Hu; Andrew Fong; Leena Chong; Amy Teh
Journal:  J Appl Clin Med Phys       Date:  2018-08-19       Impact factor: 2.102

7.  Evaluation of organ motion-based robust optimisation for VMAT planning for breast and internal mammary chain radiotherapy.

Authors:  Alex Dunlop; Ruth Colgan; Anna Kirby; Alison Ranger; Irena Blasiak-Wal
Journal:  Clin Transl Radiat Oncol       Date:  2019-04-08

Review 8.  Target motion management in breast cancer radiation therapy.

Authors:  Elham Piruzan; Naser Vosoughi; Seied Rabi Mahdavi; Leila Khalafi; Hojjat Mahani
Journal:  Radiol Oncol       Date:  2021-10-08       Impact factor: 2.991

9.  A study of the dosimetric impact of daily setup variations measured with cone-beam CT on three-dimensional conformal radiotherapy for early-stage breast cancer delivered in the prone position.

Authors:  Annie Xiao; Jessica Jutzy; Greg Hubert; Meghan Edens; Maxine Washington; Yasmin Hasan; Steven J Chmura; Hania A Al-Hallaq
Journal:  J Appl Clin Med Phys       Date:  2020-10-30       Impact factor: 2.102

10.  Single click automated breast planning with iterative optimization.

Authors:  Ben Archibald-Heeren; Mikel Byrne; Yunfei Hu; Guilin Liu; Nick Collett; Meng Cai; Yang Wang
Journal:  J Appl Clin Med Phys       Date:  2020-10-05       Impact factor: 2.243

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.