| Literature DB >> 27580732 |
Arkadiusz Lubas1, Anna Wojtecka2, Jerzy Smoszna2, Piotr Koziński3, Emilia Frankowska3, Stanisław Niemczyk2.
Abstract
PURPOSE: Renal biopsy-related arteriovenous fistula (RB-AVF), although usually asymptomatic, may sometimes result in serious clinical implications. The aim of the study was to prospectively evaluate the incidence of RB-AVF in native kidneys, together with the assessment of hemodynamic characteristics and the impact of the histopathological results of biopsy.Entities:
Keywords: Arteriovenous fistula; Renal biopsy; Resistance index
Mesh:
Year: 2016 PMID: 27580732 PMCID: PMC5031753 DOI: 10.1007/s11255-016-1411-z
Source DB: PubMed Journal: Int Urol Nephrol ISSN: 0301-1623 Impact factor: 2.370
Fig. 1Renal biopsy-related arteriovenous fistulas detected in color Doppler
Fig. 2Doppler hemodynamic assessment of renal biopsy-related arteriovenous fistulas
Comparison of demographic, biochemical and 2D ultrasound data between groups with and without renal biopsy-related arteriovenous fistula
| RB-AVF ( | PRB without fistula ( |
| |
|---|---|---|---|
| Age (years) | 40.5 ± 14.7 | 47.2 ± 15.1 | 0.058 |
| BMI (kg/m2) | 25.3 ± 4.5 | 26.7 ± 4.5 | 0.165 |
| Creatinine (mg/dl) | 1.60 ± 1.51 | 1.67 ± 1.18 | 0.319 |
| Proteinuria (g/24 h)a | 1.60 [0.13–13.4] | 3.16 [0.00–29.50] | 0.073 |
| Renal length (mm) | 117.5 ± 5.2 | 116.0 ± 13.1 | 0.696 |
| Parenchymal thickness | 16.3 ± 2.9 | 16.0 ± 3.2 | 0.750 |
| Maximal hematoma diameter (mm) | 48.7 ± 23.9 | 34.5 ± 19.9 | 0.005 |
a Median [range]
Comparison of renal biopsy findings between groups with and without renal biopsy-related arteriovenous fistula
| RB-AVF | PRB without fistula |
| |
|---|---|---|---|
| Number of glomeruli | 11.9 ± 7.1 | 16.9 ± 9.6 | 0.015 |
| Interstitial inflammationa | 1 [0–4] | 2 [0–4] | 0.511 |
| Interstitial fibrosisa | 2 [0–4] | 2 [0–4] | 0.599 |
| Tubular atrophya | 2 [0–4] | 2 [0–4] | 0.725 |
| Arterial narrowinga | 1 [0–3] | 1 [0–3] | 0.714 |
| Arterial hyalinosisa | 0 [0–4] | 0 [0–4] | 0.469 |
RB-AVF renal biopsy-related arteriovenous fistula, RB renal biopsy
aMedian [range]
Results of Doppler study on renal biopsy-related arteriovenous fistulas
| Normal renal segmental artery | Renal segmental artery supplying RB-AVF |
| |
|---|---|---|---|
| RI | 0.673 ± 0.052 | 0.439 ± 0.069 | <0.001 |
| FV (cm/s) | 43.43 ± 12.15 | 86.25 ± 31.92 | <0.001 |
| dRIa | 0.252 ± 0.104 [range 0.132–0.615] | – | |
| dFV (cm/s)a | 45.9 ± 20.0 [range 4.0–97.9] | – | |
RB-AVF renal biopsy-related arteriovenous fistula, RI resistive index, dRI the difference between resistive indexes in normal and feeding arteriovenous fistula segmental arteries, FV maximal flow velocity, dFV the difference between maximal flow velocities in feeding arteriovenous fistula and normal segmental arteries
aMedian [range]
Fig. 3Hyperechogenic area in the neighborhood of the arteriovenous fistula