Literature DB >> 27575779

Insertional depth-dependent intracochlear pressure changes in a model of cochlear implantation.

Marlene Mittmann1, Arneborg Ernst1, Philipp Mittmann1, Ingo Todt1.   

Abstract

CONCLUSION: Over time, a homogenous increase in intracochlear pressure was seen in every experiment. Significant reductions in terms of amplitude variation and insertion depth were observed over time, using the one-point-supported insertion method. The frequency of peaks between the thirds was significantly lower when using the two-points-supported insertion method.
OBJECTIVES: The preservation of residual hearing and minimization of intracochlear trauma are two of the major goals in modern cochlear implantation (CI) surgery. It is assumed that intracochlear pressure measurements yield information about the intracochlear behavior of the electrode itself in the cochlea. The aim of this study was to investigate temporal intracochlear fluid pressure changes using two different kinds of insertion conditions.
METHOD: Cochlear implantations with the Advanced Bionics IJ® electrode were performed in an artificial cochlear model with a constant insertional speed of 0.5 mm/s provided by a linear actor. Amplitude pressure changes and number of pressure peaks were evaluated for every part. RESULT: Intracochlear fluid pressure changes are assumed to affect the preservation of residual hearing and should be minimized. The stability and reduction of movement of a lateral wall IJ® electrode increase at deeper insertion and affect intracochlear fluid pressure amplitude.

Entities:  

Keywords:  Intracochlear pressure; cochlear implant; hearing preservation; insertion trauma; insertional depth; residual hearing

Mesh:

Year:  2016        PMID: 27575779     DOI: 10.1080/00016489.2016.1219918

Source DB:  PubMed          Journal:  Acta Otolaryngol        ISSN: 0001-6489            Impact factor:   1.494


  3 in total

1.  Lateral Semicircular Canal Pressures During Cochlear Implant Electrode Insertion: a Possible Mechanism for Postoperative Vestibular Loss.

Authors:  Renee M Banakis Hartl; Nathaniel T Greene; Herman A Jenkins; Stephen P Cass; Daniel J Tollin
Journal:  Otol Neurotol       Date:  2018-07       Impact factor: 2.311

2.  Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion: Effect of Micro-mechanical Control on Limiting Pressure Trauma.

Authors:  Renee M Banakis Hartl; Christopher Kaufmann; Marlan R Hansen; Daniel J Tollin
Journal:  Otol Neurotol       Date:  2019-07       Impact factor: 2.311

3.  Influence of Cochlear Implantation on Vestibular Function in Children With an Enlarged Vestibular Aqueduct.

Authors:  Ruijie Wang; Daogong Zhang; Jianfen Luo; Xiuhua Chao; Jiliang Xu; Xianfeng Liu; Zhaomin Fan; Haibo Wang; Lei Xu
Journal:  Front Neurol       Date:  2021-04-21       Impact factor: 4.003

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.