Literature DB >> 27574251

Dynamic hip screw fixation versus multiple screw fixation for intracapsular hip fracture.

P Jettoo1, P James2.   

Abstract

PURPOSE: To compare dynamic hip screw (DHS) fixation with multiple screw fixation for intracapsular hip fractures in terms of complications and conversion to hemiarthroplasty or total hip arthroplasty (THA).
METHODS: Records of 52 884 patients aged ≥50 years who underwent internal fixation using a dynamic hip screw (n=18 014, 34.1%) or multiple screws (n=34 870, 65.9%) for intracapsular femoral neck fracture from September 2007 to September 2013 were extracted from the hospital admission database that covers all admissions to the National Health Service hospitals in England using the ICD-10 and OPCS-4 codes. Gender, age, and Charlson comorbidity score of each patient were recorded, as were complications at specific time intervals and revision to hemiarthroplasty or THA at one and 4 years.
RESULTS: Compared with DHS fixation, multiple screw fixation resulted in shorter hospital stay (15 vs. 13 days, p<0.001) and lower rates of 30-day myocardial infarction (2% vs. 1.5%, p=0.022), 30-day lower respiratory tract infection (12.4% vs. 10.6%, p=0.001), 90-day mortality (10.4% vs. 8.6%, p=0.001), and avascular necrosis (0.1% vs. 0.06%, p=0.032), but a higher rate of conversion to hemiarthroplasty or THA at one or 4 years (all p<0.001).
CONCLUSION: Multiple screw fixation for intracapsular hip fracture was associated with a higher conversion rate to hemiarthroplasty or THA at one and 4 years, compared with DHS fixation.

Entities:  

Keywords:  hip fractures; postoperative complications

Mesh:

Year:  2016        PMID: 27574251     DOI: 10.1177/1602400204

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  5 in total

Review 1.  Classifications in Brief: Garden Classification of Femoral Neck Fractures.

Authors:  Jillian M Kazley; Samik Banerjee; Mostafa M Abousayed; Andrew J Rosenbaum
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

2.  A Comparison of Dynamic Hip Screw and Two Cannulated Screws in the Treatment of Undisplaced Intracapsular Neck Fractures-Two-Year Follow-Up of 453 Patients.

Authors:  Harald Kurt Widhalm; Richard Arnhold; Hannes Beiglböck; Alexandru Munteanu; Nikolaus Wilhelm Lang; Stefan Hajdu
Journal:  J Clin Med       Date:  2019-10-12       Impact factor: 4.241

3.  Curative efficacy of surgical procedures for older patients with femoral neck fracture: a network meta-analysis and systematic review.

Authors:  Lanxin Cui; Shishun Zhao; Heng Tian; Wenlai Guo; Xiaoming Dong
Journal:  J Orthop Surg Res       Date:  2022-03-02       Impact factor: 2.359

Review 4.  Dynamic hip screws versus cannulated screws for femoral neck fractures: a systematic review and meta-analysis.

Authors:  Lang Li; Xue Zhao; Xiaodong Yang; Xueyang Tang; Ming Liu
Journal:  J Orthop Surg Res       Date:  2020-08-26       Impact factor: 2.359

5.  Surgical site infection after hip fracture surgery: a systematic review and meta-analysis of studies published in the UK.

Authors:  James Masters; David Metcalfe; Joon Soo Ha; Andrew Judge; Matthew L Costa
Journal:  Bone Joint Res       Date:  2020-09-03       Impact factor: 5.853

  5 in total