Literature DB >> 27572233

Simulation of mechanical behavior and optimization of simulated injection molding process for PLA based antibacterial composite and nanocomposite bone screws using central composite design.

Behzad Shiroud Heidari1, Erfan Oliaei1, Hadi Shayesteh2, Seyed Mohammad Davachi3, Iman Hejazi1, Javad Seyfi4, Mozhgan Bahrami5, Hamid Rashedi6.   

Abstract

In this study, injection molding of three poly lactic acid (PLA) based bone screws was simulated and optimized through minimizing the shrinkage and warpage of the bone screws. The optimization was carried out by investigating the process factors such as coolant temperature, mold temperature, melt temperature, packing time, injection time, and packing pressure. A response surface methodology (RSM), based on the central composite design (CCD), was used to determine the effects of the process factors on the PLA based bone screws. Upon applying the method of maximizing the desirability function, optimization of the factors gave the lowest warpage and shrinkage for nanocomposite PLA bone screw (PLA9). Moreover, PLA9 has the greatest desirability among the selected materials for bone screw injection molding. Meanwhile, a finite element analysis (FE analysis) was also performed to determine the force values and concentration points which cause yielding of the screws under certain conditions. The Von-Mises stress distribution showed that PLA9 screw is more resistant against the highest loads as compared to the other ones. Finally, according to the results of injection molding simulations, the design of experiments (DOE) and structural analysis, PLA9 screw is recommended as the best candidate for the production of biomedical materials among all the three types of screws.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Central composite design; Injection molding simulation; PLA bone screw; Shrinkage and warpage; Structural analysis

Mesh:

Substances:

Year:  2016        PMID: 27572233     DOI: 10.1016/j.jmbbm.2016.08.008

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  3 in total

Review 1.  Recent progress in minimizing the warpage and shrinkage deformations by the optimization of process parameters in plastic injection molding: a review.

Authors:  Nan-Yang Zhao; Jiao-Yuan Lian; Peng-Fei Wang; Zhong-Bin Xu
Journal:  Int J Adv Manuf Technol       Date:  2022-02-10       Impact factor: 3.563

Review 2.  Natural, synthetic and commercially-available biopolymers used to regenerate tendons and ligaments.

Authors:  Behzad Shiroud Heidari; Rui Ruan; Ebrahim Vahabli; Peilin Chen; Elena M De-Juan-Pardo; Minghao Zheng; Barry Doyle
Journal:  Bioact Mater       Date:  2022-04-13

Review 3.  Recent Trends, Technical Concepts and Components of Computer-Assisted Orthopedic Surgery Systems: A Comprehensive Review.

Authors:  Jan Kubicek; Filip Tomanec; Martin Cerny; Dominik Vilimek; Martina Kalova; David Oczka
Journal:  Sensors (Basel)       Date:  2019-11-27       Impact factor: 3.576

  3 in total