Literature DB >> 27570111

Glucose metabolism-weighted imaging with chemical exchange-sensitive MRI of 2-deoxyglucose (2DG) in brain: Sensitivity and biological sources.

Tao Jin1, Hunter Mehrens2, Ping Wang2, Seong-Gi Kim3.   

Abstract

Recent proof-of-principle studies have demonstrated the feasibility of measuring the uptake and metabolism of non-labeled 2-deoxy-D-glucose (2DG) by a chemical exchange-sensitive spin-lock (CESL) MRI approach. In order to gain better understanding of this new approach, we performed dynamic in vivo CESL MRI on healthy rat brains with an intravenous injection of 2DG under various conditions at 9.4T. For three 2DG doses of 0.25, 0.5 and 1g/kg, we found that 2DG-CESL signals increased linearly with injection dose at the initial (<20min) but not the later period (>40min) suggesting time-dependent differential weightings of 2DG transport and metabolism. Remaining 2DG-CESL studies were performed with 0.25g/kg 2DG. Since a higher isoflurane level reduces glucose metabolism and increases blood flow, 2DG-CESL was measured under 0.5%, 1.5% and 2.2% isoflurane. The 2DG-CESL signal was reduced at higher isoflurane levels correlating well with the 2DG phosphorylation in the intracellular space. To detect regional heterogeneities of glucose metabolism, 2DG-CESL with 0.33×0.33×1.50mm3 resolution was obtained, which indeed showed a higher response in the cortex compared to the corpus callosum. Lastly, unlike CESL MRI with the injection of non-transportable mannitol, the 2DG-CESL response decreased with an increased spin-lock pulse power confirming that 2DG-CESL is dominated by chemical exchange processes in the extravascular space. Taken together, our results showed that 2DG-CESL MRI signals mainly indicate glucose transport and metabolism and may be a useful biomarker for metabolic studies of normal and diseased brains. Copyright Â
© 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CESL; CEST; CMRglu; Glucose metabolism; Glucose transport; MRI; PET

Mesh:

Substances:

Year:  2016        PMID: 27570111      PMCID: PMC5124509          DOI: 10.1016/j.neuroimage.2016.08.040

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  39 in total

1.  Prediction of cognitive decline in normal elderly subjects with 2-[(18)F]fluoro-2-deoxy-D-glucose/poitron-emission tomography (FDG/PET).

Authors:  M J de Leon; A Convit; O T Wolf; C Y Tarshish; S DeSanti; H Rusinek; W Tsui; E Kandil; A J Scherer; A Roche; A Imossi; E Thorn; M Bobinski; C Caraos; P Lesbre; D Schlyer; J Poirier; B Reisberg; J Fowler
Journal:  Proc Natl Acad Sci U S A       Date:  2001-08-28       Impact factor: 11.205

2.  A method for measuring cerebral glucose metabolism in vivo by 13C-NMR spectroscopy.

Authors:  David M Cohen; Jingna Wei; E O'Brian Smith; Xiaolian Gao; Michael J Quast; Louis Sokoloff
Journal:  Magn Reson Med       Date:  2002-12       Impact factor: 4.668

3.  Quantitative T(1rho) and adiabatic Carr-Purcell T2 magnetic resonance imaging of human occipital lobe at 4 T.

Authors:  Heidi I Gröhn; Shalom Michaeli; Michael Garwood; Risto A Kauppinen; Olli H J Gröhn
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

4.  Disorders of glucose metabolism in acute stroke patients: an underrecognized problem.

Authors:  Karl Matz; Katharina Keresztes; Claudia Tatschl; Monika Nowotny; Alexandra Dachenhausen; Alexandra Dachenhausenm; Michael Brainin; Jaakko Tuomilehto
Journal:  Diabetes Care       Date:  2006-04       Impact factor: 19.112

5.  In vivo measurements of brain glucose transport using the reversible Michaelis-Menten model and simultaneous measurements of cerebral blood flow changes during hypoglycemia.

Authors:  I Y Choi; S P Lee; S G Kim; R Gruetter
Journal:  J Cereb Blood Flow Metab       Date:  2001-06       Impact factor: 6.200

6.  Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protons.

Authors:  Tao Jin; Joonas Autio; Takayuki Obata; Seong-Gi Kim
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

7.  Examination of potential mechanisms in the enhancement of cerebral blood flow by hypoglycemia and pharmacological doses of deoxyglucose.

Authors:  N Horinaka; N Artz; J Jehle; S Takahashi; C Kennedy; L Sokoloff
Journal:  J Cereb Blood Flow Metab       Date:  1997-01       Impact factor: 6.200

8.  Chemical exchange saturation transfer (CEST): what is in a name and what isn't?

Authors:  Peter C M van Zijl; Nirbhay N Yadav
Journal:  Magn Reson Med       Date:  2011-02-17       Impact factor: 4.668

9.  Natural D-glucose as a biodegradable MRI contrast agent for detecting cancer.

Authors:  Kannie W Y Chan; Michael T McMahon; Yoshinori Kato; Guanshu Liu; Jeff W M Bulte; Zaver M Bhujwalla; Dmitri Artemov; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2012-10-16       Impact factor: 4.668

10.  Measurement of regional cerebral glucose uptake by magnetic resonance spin-lock imaging.

Authors:  Zhongliang Zu; John Spear; Hua Li; Junzhong Xu; John C Gore
Journal:  Magn Reson Imaging       Date:  2014-06-21       Impact factor: 2.546

View more
  17 in total

1.  Spin-lock imaging of 3-o-methyl-D glucose (3oMG) in brain tumors.

Authors:  Zhongliang Zu; Xiaoyu Jiang; Junzhong Xu; John C Gore
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

2.  Spin-lock imaging of early tissue pH changes in ischemic rat brain.

Authors:  Zhongliang Zu; Aqeela Afzal; Hua Li; Jingping Xie; John C Gore
Journal:  NMR Biomed       Date:  2018-02-09       Impact factor: 4.044

3.  Chemical exchange-sensitive spin-lock MRI of glucose analog 3-O-methyl-d-glucose in normal and ischemic brain.

Authors:  Tao Jin; Hunter Mehrens; Ping Wang; Seong-Gi Kim
Journal:  J Cereb Blood Flow Metab       Date:  2017-05-09       Impact factor: 6.200

4.  Spin-lock imaging of exogenous exchange-based contrast agents to assess tissue pH.

Authors:  Zhongliang Zu; Hua Li; Xiaoyu Jiang; John C Gore
Journal:  Magn Reson Med       Date:  2017-03-20       Impact factor: 4.668

5.  Chemical exchange-sensitive spin-lock (CESL) MRI of glucose and analogs in brain tumors.

Authors:  Tao Jin; Bistra Iordanova; T Kevin Hitchens; Michel Modo; Ping Wang; Hunter Mehrens; Seong-Gi Kim
Journal:  Magn Reson Med       Date:  2018-03-23       Impact factor: 4.668

6.  Dynamic contrast-enhanced CEST MRI using a low molecular weight dextran.

Authors:  Zheng Han; Chuheng Chen; Xiang Xu; Renyuan Bai; Verena Staedtke; Jianpan Huang; Kannie W Y Chan; Jiadi Xu; David O Kamson; Zhibo Wen; Linda Knutsson; Peter C M van Zijl; Guanshu Liu
Journal:  NMR Biomed       Date:  2021-11-15       Impact factor: 4.044

7.  Spin-lock imaging of intrinsic susceptibility gradients in tumors.

Authors:  Zhongliang Zu; Vaibhav Janve; John C Gore
Journal:  Magn Reson Med       Date:  2019-12-27       Impact factor: 4.668

Review 8.  Sugar-based biopolymers as novel imaging agents for molecular magnetic resonance imaging.

Authors:  Zheng Han; Guanshu Liu
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2019-01-22

9.  Chemical exchange sensitive MRI of glucose uptake using xylose as a contrast agent.

Authors:  Jicheng Wang; Mitsuhiro Fukuda; Julius Juhyun Chung; Ping Wang; Tao Jin
Journal:  Magn Reson Med       Date:  2020-10-26       Impact factor: 4.668

10.  CEST MRI of 3-O-methyl-D-glucose uptake and accumulation in brain tumors.

Authors:  Akansha Ashvani Sehgal; Yuguo Li; Bachchu Lal; Nirbhay N Yadav; Xiang Xu; Jiadi Xu; John Laterra; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2018-09-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.