Literature DB >> 2756883

Improved sensitivity of color Doppler by SH U 454.

H Becher1, R Schlief.   

Abstract

SH U 454, a suspension of galactose microparticles, provides microbubbles (97% less than 7 microns) in variable, reproducible concentrations. Its influence on color Doppler imaging was evaluated in a flow model study and in a clinical study. In the flow model, increasing attenuation (up to 11.4 dB/MHz) impaired the signal to noise ratio and decreased the sensitivity for detecting flow velocities. Thus, flow signals were obtained with flow velocities greater than 3 cm/s (0.1 dB/MHz), greater than 9 cm/s (5.7 dB/MHz) and greater than 17 cm/s (11.4 dB/MHz). After injection of SH U 454 (200 mg/ml), velocities down to 3 cm/s were detected even with high attenuation (11.4 dB/MHz). Color Doppler imaging was performed before and after intravenous injection of 2 ml, 3 ml and 4 ml of SH U 454 (200 mg/ml) in 22 adult patients, and the maximal color-coded areas of diastolic blood flow were determined in the right atrium and ventricle. In 19 of 22 patients, the displayed color-coded areas increased after injection of SH U 454. The diastolic blood flow was imaged on 14 +/- 8% (mean +/- 1 standard deviation) of the cross-sectional area of the right ventricle (4-chamber view) without SH U 454, compared with 39 +/- 15% with 3 ml of SH U 454 (p less than 0.001). For the right atrium, the area displayed by color Doppler increased from 9 +/- 13 to 62 +/- 25% (p less than 0.001). The variability of the measurements from patient to patient after injection of SH U 454 was 5.9 +/- 4% as compared with 10.7 +/- 6.9% without SH U 454 (p less than 0.05). These findings indicate that the intravenous injection of SH U 454 increases the sensitivity of color Doppler imaging for detection of blood flow by improving the signal to noise ratio.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2756883     DOI: 10.1016/0002-9149(89)90538-9

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  5 in total

Review 1.  Clinical uses of microbubbles in diagnosis and treatment.

Authors:  David Cosgrove; Chris Harvey
Journal:  Med Biol Eng Comput       Date:  2009-02-10       Impact factor: 2.602

Review 2.  The use of microbubbles in Doppler ultrasound studies.

Authors:  Piero Tortoli; Francesco Guidi; Riccardo Mori; Hendrik J Vos
Journal:  Med Biol Eng Comput       Date:  2008-11-11       Impact factor: 2.602

3.  Use of sonicated albumin (Infoson) to enhance arterial spectral and color Doppler imaging.

Authors:  A Abildgaard; T S Egge; N E Klow; J A Jakobsen
Journal:  Cardiovasc Intervent Radiol       Date:  1996 Jul-Aug       Impact factor: 2.740

4.  Vaginal axis after abdominal, vaginal and laparoscopic hysterectomy: a preliminary study with perineal ultrasonography using contrast medium.

Authors:  H S Virtanen; J I Mäkinen; M A Haarala; P J Kiilholma
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  1996

Review 5.  New ultrasound contrast agents for left ventricular and myocardial opacification.

Authors:  J D Kasprzak; F J Ten Cate
Journal:  Herz       Date:  1998-12       Impact factor: 1.443

  5 in total